Event Group - Base Controller Diagnostic
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_CONTROLLER_ID
RecoveryFailureType - REC_BASE_CONTROLLER_DIAG_FAILED ( offlineCtl.html )

MEL_EV_IOC_CONTROLLER_FAILURE - 0x5101

This event occurs when: One or more diagnostic tests detected that one or more component on the alternate
controller is not functioning as desired. As a result, the alternate controller is locked down.
Event Name - Base Controller Diagnostic On Alternate Controller Failed
Event description: Base controller diagnostic on alternate controller failed
Event Group - Base Controller Diagnostic
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_IOC_DIAG_FAIL ( ctrlIocDiagFailed.html )

MEL_EV_IOC_FAILURE - 0x5102

This event occurs when: An IOC diagnostic test has detected a failure. As a result, the controller is locked
down.
Event Name - IOC Fault Diagnostic Failure
Event description: IOC fault diagnostic failure has been detected
Event Group - Base Controller Diagnostic
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
.