Event Name - ESM Version Mismatch
Event description: IOM (ESM) firmware mismatch
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_ESM_CODE_VERSION_MISMATCH ( trayCodeMismatch.html )

MEL_EV_BYPASS_GENERIC - 0x2823

This event occurs when: A drive is bypassed on both ports.
Event Name - Bypass Generic
Event description: Drive by-passed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_DRIVE_BYPASSED_CAUSE_UNKNOWN ( bypassedDrive.html )

MEL_EV_CONT_REDUNDANCY_LOSS - 0x2829

This event occurs when: An array determines that one controller is in a failed mode.
Event Name - Cont Redundancy Loss
Event description: Controller redundancy lost
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
.