Mel_Ev_Persist_Mpe - 0X2604; Mel_Ev_Sod_Fde_Inconsistent_Array_Lock_Key - 0X2607; Mel_Ev_Multiple_Mismatched_Key_Ids - 0X2705 - Lenovo ThinkSystem DE Series Hardware Installation And Maintenance Manual

For 2u enclosures
Hide thumbs Also See for ThinkSystem DE Series:
Table of Contents

Advertisement

RecoveryFailureType - N/A

MEL_EV_PERSIST_MPE - 0x2604

This event occurs when: A SOD detects that the persistent memory parity error state has been set. RPA
memory has reported a persistent error, this generally results in a lock-down.
Event Name - Persistent Memory Parity Error
Event description: Persistent controller memory parity error
Event Group - Start of Day
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A

MEL_EV_SOD_FDE_INCONSISTENT_ARRAY_LOCK_KEY - 0x2607

This event occurs when: An inconsistent array lock key situation is detected.
Event Name - FDE Inconsistent Array Lock Key
Event description: Inconsistent security (FDE) storage array lock key
Event Group - Start of Day
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SECURITY_KEY_INCONSISTENT ( fdeInconsistentSecurityKey.html )

MEL_EV_MULTIPLE_MISMATCHED_KEY_IDS - 0x2705

This event occurs when: Multiple mismatched drive lock key ids are detected by the firmware.
Event Name - Multiple Mismatched Key Ids Found
Event description: Multiple mismatched key ids found
Event Group - Start of Day