Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_CTL_MISMATCH ( ctrlMismatch.html )

MEL_EV_DRIVE_TRAYS_NOT_GROUPED_TOGETHER - 0x2835

This event occurs when: A storage array configuration requires drive trays to be sequentially cabled together,
but they are not.
Event Name - Drive Trays Not Grouped Together
Event description: Drive trays not cabled correctly
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DRIVE_TRAYS_NOT_GROUPED_TOGETHER ( driveTrayCluster.html )

MEL_EV_DISCRETE_LINE_FAIL - 0x2836

This event occurs when: A discrete line test has failed, due to either a fault Controller or a faulty Interconnect
Module.
Event Name - Discrete Line Failure
Event description: Discrete lines diagnostic failure
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_I2C_VALUE
RecoveryFailureType - REC_FAILED_DISCRETE_LINE ( discreteLineFailed.html )

MEL_EV_ICC_REMOVED - 0x2838

This event occurs when: An interconnect or battery canister is removed from the controller enclosure.
Event Name - Interconnect CRU Removed
.