Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume Group (0x0, 0xE), Disk Pool (0x3, 0x2)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_VOLUME_GROUP_MISSING ( missingVGorDP.html )

MEL_EV_VOLUME_GROUP_INCOMPLETE - 0x2275

This event occurs when: A volume group becomes incomplete because one or more drives in the group have
been removed.
Event Name - Volume Group Incomplete
Event description: Component incomplete
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume Group (0x0, 0xE), Disk Pool (0x3, 0x2)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_VOLUME_GROUP_INCOMPLETE ( incompleteVGorDP.html )

MEL_EV_DRIVE_UNSUP_INTERPOSER_FW_VER - 0x2276

This event occurs when: The firmware version in an interposer is incompatible with the drive behind the
interposer. New interposer firmware is necessary.
Event Name - Interposer FW Version Unsupported
Event description: Interposer FW version unsupported
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)