LEDs on the operator display panel

Each controller shelf or drive shelf has LEDs located on the operator display panel (ODP). The ODP is visible
through the left end cap of a controller shelf or drive shelf.
The following example shows the LEDs on the ODP of the DE4000H (12 drives) controller shelf. The LEDs on
ODP also apply to DE2000H (12 or 24 drives), DE4000H (24 drives), DE4000F, DE6000H (24 drives), and
DE6000F controller shelves. The LEDs on ODP also apply to DE120S and DE240S drive shelves.
Figure 15. LEDs on the operator display panel
Components
1
Power LED
2
Attention LED (front)
3
Location LED (front)
4
Shelf ID digital display
176
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Status
Description
Solid green
One or more power supplies are delivering power to the shelf.
Off
No power supply is delivering power to the shelf.
Solid amber
There is an error with the function of one or more of the following:
shelf, drives, IOMs, power supplies, or fans.
Off
The system is operating normally.
Solid blue or
The shelf location LED is manually activated to help locating the
blinking blue
shelf.
Note: The location LED turns off automatically after 30 minutes.
Off
The location LED is not activated.
Number displayed