Enable Switch Or Contact Wired To The Enable Connector - Baldor BC142 Installation And Operation Manual

Dc control. dc drive
Hide thumbs Also See for BC142:
Table of Contents

Advertisement

6.7 Enable Circuit Connection – The control can be started and stopped with an Enable Circuit (close to run),
as described below.
WARNING! The Enable Circuit is never to be used as a Safety Disconnect since it is not
!
fail-safe. Use only the AC line for this purpose.
6.7.1 Enable Switch or Contact Wired to the Enable Connector – Using the wired mating connector that
is supplied with the control, wire the switch or contact to the Enable connector (CONN1), as shown in
Figure 5. When the switch or contact is closed, the motor will accelerate to the Main Speed
Potentiometer setting. When the switch or contact is opened, the motor will decelerate to stop. An
open collector (PNP) can be wired in lieu of a switch or contact.
Notes: 1. To use
the Enable Circuit,
remove the jumper
that is factory
installed on
CONN1. 2. The
deceleration time
can only be made
longer than the
normal coasting
time of the load.
6.7.2 Enable Switch or Contact Wired to the Main Speed Potentiometer – Wire the switch or contact in
series with the Main Speed Potentiometer high side and Terminal "P3" on the control, as shown in
Figure 6, on page 17. Be sure the jumper is installed on the Enable Connector (CONN1). When the
switch or contact is closed, the motor will accelerate to the Main Speed Potentiometer setting. When
the switch or contact is opened, the motor will decelerate to the MIN Trimpot setting (factory set to 0
16
FIGURE 5 – ENABLE SWITCH OR CONTACT WIRED TO THE ENABLE CONNECTOR
Remove this jumper to install
the Mating Connector
Enable Switch
or Contact
(Close to Run)
(Open to Stop)
MAX
Open Collector
(On to Run)
(Off to Stop)
MAX
MAX

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bc141Bc142-6