TABLE 5 – PLUG-IN HORSEPOWER RESISTOR® & ARMATURE FUSE KIT SELECTION
90 - 130 Volt
DC Motors
(HP)
1/100
1/50
1/30
1/20
1/15
1/12
1/8
1/6
1/4
1/3
1/2
3/4
1*
1
1
*
2
* Indicates an Auxiliary Heat Sink (Catalog No. BC143, or equivalent) must be used.

10 RECOMMENDED HIGH VOLTAGE DIELECTRIC WITHSTAND TESTING (Hi-Pot Testing)

Testing agencies such as UL, CSA, etc., usually require that equipment undergo a hi-pot test. In order to prevent
catastrophic damage to the control, which has been installed in the equipment, it is recommended that the follow-
ing procedure be followed. A typical hi-pot test setup is shown in Figure 13 on page 23. All controls have been
factory hi-pot tested in accordance with UL requirements.
!
WARNING! When performing the hi-pot test, disconnect the AC power.
22
180 Volt
Approximate
DC Motors
Motor Current
(HP)
(Amps DC)
1/50
.2
1/25
.3
1/15
.33
1/10
.5
1/8
.8
1/6
.85
1/4
1.3
1/3
2
1/2
2.5
3/4
3.3
1
5
1
1
7.5
2
2*
10
3*
15
Plug-In Horsepower
Resistor® and Armature
Fuse Kit Catalog No.
BR1000
BR0510
BR0350
BR0250
BR0251
BR0180
BR0100
BR0101
BR0050
BR0035
BR0025
BR0015
BR0010
BR0006
Plug-In Horsepower
Resistor®
Fuse Rating
Value (Ohms)
1
.51
.35
.25
.25
.18
.1
.1
.05
.035
.025
.015
.01
.006
Armature
(Amps)
.5
.5
.5
.75
1
1.25
2
2.5
4
5
8
12
15