Advertisement

Physical Interface
5.7.4
Selecting the Input Line as the Source Signal for
a Camera Function
You can select input line 1 to act as the source signal for the following camera functions:
the acquisition start trigger
the frame start trigger
the frame counter reset
the trigger input counter reset
Note that when the input line has been selected as the source signal for a camera function, you
must apply an electrical signal to the input line that is appropriately timed for the function.
For more information about selecting input line 1 as the source signal for a camera function, see
Section 6.1 on
page 51