Response Time; Selecting A Source Signal For The Output Line - Basler ace acA640-90gm User Manual

Gige cameras
Table of Contents

Advertisement

Physical Interface
5.8.3

Response Time

The information in this section assumes that the output circuit on your camera is
designed as in the typical voltage output circuit shown in
The response times for the output lines on your camera will typically fall into the
ranges specified below. The exact response time for your specific application will
depend on the external resistor and the applied voltage you use.
Response times for the output line on the camera are as shown in Figure 29.
Level on
Out_1_Ctrl
Voltage Present
on the Camera's
Output Line
Fig. 29: Output Line Response Times
Time Delay Rise (TDR) = 40 µs
Rise Time (RT) = 20 µs to 70 µs
Time Delay Fall (TDF) = 0.6 µs
Fall Time (FT) = 0.7 µs to 1.4 µs
5.8.4

Selecting a Source Signal for the Output Line

To make the physical output line useful, you must select a source signal for the line. The camera
has several standard output signals available and any one of them can be selected to act as the
source signal for the output line.
For more information about selecting a source signal for the output line, see Section 6.2 on
page
54.
50
TDR
90%
RT
Time
TDF
FT
90%
Section
5.8.2.
Not to Scale
Basler ace GigE