For more information about input line pin assignments and pin numbering, see Section 5.2 on
page
36.
For more information about how to use an externally generated frame start trigger (ExFSTrig) signal
to control acquisition start, see Section 7.4.3 on
For more information about configuring the input line, see Section 6.1 on
5.7.3
Response Time
The response times for the input line on the camera are as shown in Figure 25.
Voltage Applied
to the Camera's
Input Line
Level of
Camera's
Internal Input
Circuit
Fig. 25: Input Line Response Times
Time Delay Rise (TDR) = 1.3 µs to 1.6 µs
Time Delay Fall (TDF) = 40 µs to 60 µs
Basler ace GigE
page
2.2 V
(10.4 V with PLC cable)
Time
TDR
82.
page
Not to Scale
1.4 V
(8.4 V with PLC cable)
TDF
Physical Interface
51.
45