Characteristics - Basler ace acA640-90gm User Manual

Gige cameras
Table of Contents

Advertisement

Physical Interface
5.7.2

Characteristics

The camera is equipped with one physical input line designated as Input Line 1. The input line is
accessed via the 6-pin receptacle on the back of the camera.
As shown in Figure 23, the input line is opto-isolated. See the previous section for input voltages
and their significances. The absolute maximum input voltage is +30.0 VDC. The current draw for
each input line is between 5 mA and 15 mA.
Fig. 23: Input Line Schematic
Figure 24 shows an example of a typical circuit you can use to input a signal into the camera.
Fig. 24: Typical Input Circuit
44