There are a total of 5 Group Time Zones
available for use.
Every new registered user belongs to Time
Zone 1. Default grouping combination is
Group 1 and default Group Time Zone 1.
Group time zone
Time zones
1
2
2
3
4
5
Table 1.3 Group Time Zones
Under a condition where Group 1 and
Time Zone 1 are in factory default status,
new registered user defaults in unlocking
status. If the grouping of that user does not
include in grouping combination setting,
then user can only record time attendance
but cannot unlock the door.
28 CONTENTS
Access option has 6 main functions
1
TImE zONE SETTING
To define time zone 1 to 50.
2
HOLIDay SETTINGS
To define time zone for holiday.
3
3
GROUp TImE zONES SETTINGS
To define group time zones, a group can
support up to 3 different time zones.
4
UNLOCk COmBINaTION SETTINGS
To define different time zone combina-
tions, and each combination is composed
of different groups.
5
aCCESS CONTROL paRamETERS
To define lock/unlock parameters
6
DURESS aLaRm paRamETERS
To define duress alarm parameters.
FUNCTION DESCRIpTION
DEFINITION OF TImE
zONE
TImE zONE
Range of time specified for access options.
The system can define a maximum of 50 time
zones. Each user can set a maximum of 3
times zones.
TImE REGION
A certain period of time with a format of HH:
MM–HH:MM, operates in 24-hr format and ac-
curate to the minutes. For each time zones, 7
time regions can be set.
aLL Day aCCESS
00:00 to 23:59, reader allows user to access
anytime in a day.
FORBIDDEN TImE zONE
23:59 to 00:00, reader blocks users to access
anytime in a day.