F1/2 Remote Control; Iring Diagram; S35 Steering Lever; J3 W / Multiple Input - Simrad ROBERTSON AP45 Instruction Manual

Simrad marine instruments user manual
Table of Contents

Advertisement

Page 5-30

S35 Steering Lever

F1/2 Remote Control

The unit is mounted to bulkhead or panel by two screws from the front. The cable
is connected to the junction unit according to Fig. 5-35. Interchange the port and
stbd wires to the screw terminals in the junction unit if necessary to make the
direction of the lever movement coincide with the direction of the rudder
movement.
This handheld remote control with 10 m (30 ft.) cable is connected to the control
unit as shown in Fig. 5-35.
AP45 Wiring diagram - J3 w/multiple input
Fig. 5-35
S35, F1/2 - AP45 - Wiring diagram
Fig. 5-36
Simrad Robertson AS
Egersund - Norway
Robertson AP45 Autopilot