Simrad ROBERTSON AP45 Instruction Manual page 79

Simrad marine instruments user manual
Table of Contents

Advertisement

Robertson AP45 Autopilot
Installation
The two diodes (1N4002 or similar) and the resistor can be mounted either in the
AP45 J3 connector or in the FU91 terminal board. By giving resistor R different
values, following mode changes are possible:
R = 1.0K: Auto
Dodge
R = 3.0K: Auto
Manual
R = 5.1K: Auto
Manual
See also page 2-14 for operation.
Multiple FU91 installation is not recommended with AP45 unless the optional FU-
Junction box is used. Connections are shown in Fig. 5-34
If mode switching is required, the resistor and the two diodes must be mounted
between the FU-Junction box and the AP45 Control unit.
Fig. 5-33
FU91 with mode switching
Auto
Manual
Auto
Fig. 5-34
FU91 Multiple installation
Simrad Robertson AS
Egersund - Norway
Page 5-29