Rule Target
The Rule Target items select the this and target parts of the rule structure (if conditions then do this
to target). Selecting the item and clicking Edit will display the Control Sensor selection screen.

14.3.4 Rule Status and Totals

The Status and Totals screen is the only page of Advanced Rule Parameters and is displayed by
pressing the
Rule Status
This section shows the current status of the rule.
Rule Totals
This section shows the current totals for the rule. Clicking the clear button will clear the totals.
14.4

Flow Meters

14.4.1 Overview and Operation

The Micro-Master Touch supports up to thirty two independent aggregate flow meters. Flow meters
can use any one of the main screen panel switch inputs as the pulse input and supports flow meters
that provide 1 or more pulses per litre, 10 litres, 100 litres or kilolitres.
Each flow meter can be named and can be enabled or disabled without modifying the inputs.
© 2014 Toro Australia Pty Ltd
Micro-Master Touch User Guide
icon on the Rule Edit screen.
Figure 62 - Rule Status and Totals
88
Ver 1.2, June 2014