Dismantling And Disposal - ProMinent DULCO Trans 40/1000 PVDF Operating Instructions Manual

Barrel pump
Table of Contents

Advertisement

Available languages

Available languages

Cleaning ater operation, Measures after use, Dismantling and Disposal
Cleaning after each operation
 Clean the pump by flushing an appropriate cleaning agent.
First pump the cleaning agent in circuit, then rinse with
clean detergent.
 Do not remove motor from the pump as long as there is
any back pressure.
 Before removing the motor from the pump, completely
drain pump, flexible hose and hand nozzle.
 Do not use flammable liquids to clean the pump.
 The pump and hose must be compatible with
the cleaning agent.
 The pump should not be immersed deeper into
the cleaning agent than the outlet connection.
Dismantling of pump for cleaning :
1. Remove the plug.
1. Release union nut between motor and pump.
2. Remove the motor.
3. Remove inner tube from the pump.
Measures after use
Attention!
 Empty pump, hose and fittings after every use.
 Drain hand nozzle after use. Otherwise liquid being contained
within the outlet tube will flow out without control.

Dismantling and Disposal

 Pump, hose and fittings must be emptied prior to dismantling.
 Prior to dismantling the outlet tube switch the pump off and
disconnect the mains.
 Collect environmentally harmful substances and liquids in
appropriate containers and dispose of them in an environmen-
tally sound manner.
 Dispose of scrap material and parts that cannot be repaired or
reused in an environmentally sound manner.
17

Advertisement

Table of Contents
loading

Table of Contents