Magnetically coupled centrifugal pump
®
ProMinent
von Taine
Type:
Please read the manual instructions completely before bringing the machine into service!
Damage caused by an operator´s error will cancel the right to all warranty claims!
Part-No. 987045
ProMinent Dosiertechnik GmbH • 69123 Heidelberg • Germany BA vT 009 03/06 GB
®
von Taine
®
0807 PVDF
0807 PP/FKM
0807 PP/EPDM
Serial-No.
Please enter type + serial number of the pump here !
Do not throw it away!
0807 PP and PVDF
®
von Taine
0807 PVDF/FKM
0807 PVDF/EPDM
0807 PP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the von Taine 0807 PP/FKM and is the answer not in the manual?

Questions and answers

Summary of Contents for ProMinent von Taine 0807 PP/FKM

  • Page 1 Please read the manual instructions completely before bringing the machine into service! Do not throw it away! Damage caused by an operator´s error will cancel the right to all warranty claims! Part-No. 987045 ProMinent Dosiertechnik GmbH • 69123 Heidelberg • Germany BA vT 009 03/06 GB...
  • Page 2 Imprint Imprint: Operating instructions Magnetically coupled centrifugal pump ® ® ProMinent von Taine 0807 PP and PVDF © ProMinent Dosiertechnik GmbH, 2010 ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 69123 Heidelberg Germany info@prominent.de www.prominent.de Specifications subject to change without notice !
  • Page 3: Table Of Contents

    Table of contents TABLE OF CONTENTS General information ................... 5 Authorized use of the pump ..................5 Sound intensity level ....................5 Safety........................5 Identification of safety instructions in the operating manual........5 Qualification and training of operating personnel............6 Hazards in the event of non-compliance with safety instructions........6 Compliance with regulations pertaining of safety work ..........6 Safety instructions relevant for operation ..............6 Safety instructions relevant for maintenance, inspection and assembly work ....6...
  • Page 4 Table of contents Disassembly of the pump ..................12 Re-assembly of the pump ..................13 Troubleshooting ....................15 Technical data....................16 10 Spare parts ....................... 17 10.1 Exploded view ......................17 ® 10.2 Bill of materials von Taine 0807 PP/FKM ..............18 ® 10.3 Bill of materials von Taine 0807 PVDF/FKM ............18 ®...
  • Page 5: General Information

    (see the ProMinent list of resistances) symbol • If you deliver crystallising fluids, make sure that the fluid does not crystallise within the pump.
  • Page 6: Qualification And Training Of Operating Personnel

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 2.2 Qualification and training of 2.5 Safety instructions relevant for operating personnel operation The personnel responsible for operation, If hot or cold machine components maintenance, inspection and assembly involve hazards, they must be guarded must be adequately qualified.
  • Page 7: Unauthorized Alterations And Production Of Spare Parts

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 3.2 Storage An eventual storage place must be absolutely dry. Make sure that the interior of the pump is protected from pollutants. The pump is magnetically coupled. Attention: Coming in contact with 3.3 Ambient conditions required...
  • Page 8: Materials

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 5.2 Hoses and tubes NOTE The cross-sections of the tubes must The materials used are listed on the correspond to the suction and delivery name plate or the delivery note! ports. All suction and delivery tubes to the pump housing should be free of tensile stress.
  • Page 9: Starting And Shutdown Procedures

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF WARNING Do not check the direction of rotation without having filled fluid in the pump! The motor must be equipped with a motor protection switch. The power supply must have been cut...
  • Page 10: Starting Procedure

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF Close all shut-off devices. 6.2 Starting procedure In case some fluid remains within the Switch on the motor. pump, secure the shut-off devices to Check the direction of rotation of the prevent an accidental opening.
  • Page 11 ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF WARNING Make sure there are no magnetisable metal particles in the working area if you assemble or disassemble the pump! When the complete head of the pump is assembled or disassembled, magnetic...
  • Page 12: Disassembly Of The Pump

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 7.3 Disassembly of the pump 1. Remove the 6 screws (901.1) in the pump 2. Take the suction flange (162) off the pump housing (101). housing (161). Pull the impeller with the impeller magnet (230 + 847.1) and the...
  • Page 13: Re-Assembly Of The Pump

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 7.4 Re-assembly of the pump 1. Install bearings (310.1 and 310.2) to 2. Make sure that the impeller with impeller impeller magnet (847.1) and impeller magnet (230+847.1) and bearings (230). (310.1+310.2) installed properly rotates around the center shaft.
  • Page 14 ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF WARNING Once the complete head of the pump has been assembled, the impeller (230) and the impeller magnet (847.1) should be able to slide axially on the center shaft (211)! • Any other repair than the replacement...
  • Page 15: Troubleshooting

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 8 Troubleshooting Malfunction Causes Corrective action Pump does not work when No voltage Test the voltage switched on Impurities in the pump Remove the impurities housing Magnetic clutch is Specific gravity and/or Reduce the delivery rate;...
  • Page 16: Technical Data

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 9 Technical data Order- No. 1023090 1023096 1028552 1028568 ® ® ® ® Pump type von Taine 0807 von Taine 0807 von Taine 0807 von Taine 0807 PP/FKM PVDF/FKM PP/EPDM PVDF/EPDM...
  • Page 17: Spare Parts

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 10 Spare parts 10.1 Exploded view Page...
  • Page 18: Bill Of Materials Von Taine ® 0807 Pp/Fkm

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF ® 10.2 Bill of materials von Taine 0807 PP/FKM Serial-No: Pos. Qty. Order-No. Designation Material Qty. PUMA.00.0250.071 lantern 161+314.2 PUMA.05.0050.036 pump housing with thrust ring polypropylene PUMA.05.0050.100 suction flange polypropylene PUMA.05.0050.083...
  • Page 19: Bill Of Materials Von Taine ® 0807 Pp/Epdm

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF Pos. Qty. Order-No. Designation Material Qty. PUMA.00.0090.140 mounting plate polypropylene 901.1 PUMA.05.0050.110 hexagon head cap screw M6x45 DIN931 inox 901.2 PUMA.00.0750.021 hexagon head cap screw M6x16 DIN933 inox 904.1 PUMA.05.0050.007 threaded pin M6x10 DIN914 PUMA.00.0090.030...
  • Page 20: Appendix

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF Pos. Qty. Order-No. Designation Material Qty. 310.1 PUMA.05.0050.046 bearing oxide ceramic 310.2 PUMA.05.0050.046 bearing oxide ceramic 314.1 PUMA.05.0050.040 thrust ring oxide ceramic 412.1 PUMA.05.0050.093 o-ring 90x2,5 EPDM 412.3 FISF.00.0000.180 o-ring 26x3,5 EPDM 412.4...
  • Page 21: Characteristic Curves

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 11.2 Characteristic curves ® von Taine 0807 PP/PVDF Dichte / density NPSH 1000 2000 3000 4000 5000 6000 7000 Förderleistung / capacity [l/h] 1000 2000 3000 4000 5000 6000 7000 Förderleistung / capacity [l/h]...
  • Page 22: Motor Data Sheet

    Les données techniques correspondent au descriptif du fabricant des moteurs. Les données techniques de moteurs similaires chez d´autres fabricants varient très peu. Ces données sont d´ordre général. Nr. / No. ProMinent Dosiertechnik GmbH · 69123 Heidelberg · Germany Datum / Date 05.12.2003 Page 22...
  • Page 23: Ec Declaration Of Conformity

    ® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 11.4 EC Declaration of Conformity Page...
  • Page 24 Addresses and delivery by the manufacturer / Adresses et liste des fournisseurs fourniesa par le constructeur / Para informase de las direcciones de los distribuitores, dirigirse al fabricante ® ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 • 69123 Heidelberg Germany Tel.: +49 6221 842-0 Fax.