Summary of Contents for ProMinent von Taine 0807 PP/FKM
Page 1
Please read the manual instructions completely before bringing the machine into service! Do not throw it away! Damage caused by an operator´s error will cancel the right to all warranty claims! Part-No. 987045 ProMinent Dosiertechnik GmbH • 69123 Heidelberg • Germany BA vT 009 03/06 GB...
Table of contents TABLE OF CONTENTS General information ................... 5 Authorized use of the pump ..................5 Sound intensity level ....................5 Safety........................5 Identification of safety instructions in the operating manual........5 Qualification and training of operating personnel............6 Hazards in the event of non-compliance with safety instructions........6 Compliance with regulations pertaining of safety work ..........6 Safety instructions relevant for operation ..............6 Safety instructions relevant for maintenance, inspection and assembly work ....6...
Page 4
Table of contents Disassembly of the pump ..................12 Re-assembly of the pump ..................13 Troubleshooting ....................15 Technical data....................16 10 Spare parts ....................... 17 10.1 Exploded view ......................17 ® 10.2 Bill of materials von Taine 0807 PP/FKM ..............18 ® 10.3 Bill of materials von Taine 0807 PVDF/FKM ............18 ®...
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 2.2 Qualification and training of 2.5 Safety instructions relevant for operating personnel operation The personnel responsible for operation, If hot or cold machine components maintenance, inspection and assembly involve hazards, they must be guarded must be adequately qualified.
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 3.2 Storage An eventual storage place must be absolutely dry. Make sure that the interior of the pump is protected from pollutants. The pump is magnetically coupled. Attention: Coming in contact with 3.3 Ambient conditions required...
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 5.2 Hoses and tubes NOTE The cross-sections of the tubes must The materials used are listed on the correspond to the suction and delivery name plate or the delivery note! ports. All suction and delivery tubes to the pump housing should be free of tensile stress.
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF WARNING Do not check the direction of rotation without having filled fluid in the pump! The motor must be equipped with a motor protection switch. The power supply must have been cut...
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF Close all shut-off devices. 6.2 Starting procedure In case some fluid remains within the Switch on the motor. pump, secure the shut-off devices to Check the direction of rotation of the prevent an accidental opening.
Page 11
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF WARNING Make sure there are no magnetisable metal particles in the working area if you assemble or disassemble the pump! When the complete head of the pump is assembled or disassembled, magnetic...
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 7.3 Disassembly of the pump 1. Remove the 6 screws (901.1) in the pump 2. Take the suction flange (162) off the pump housing (101). housing (161). Pull the impeller with the impeller magnet (230 + 847.1) and the...
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 7.4 Re-assembly of the pump 1. Install bearings (310.1 and 310.2) to 2. Make sure that the impeller with impeller impeller magnet (847.1) and impeller magnet (230+847.1) and bearings (230). (310.1+310.2) installed properly rotates around the center shaft.
Page 14
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF WARNING Once the complete head of the pump has been assembled, the impeller (230) and the impeller magnet (847.1) should be able to slide axially on the center shaft (211)! • Any other repair than the replacement...
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 8 Troubleshooting Malfunction Causes Corrective action Pump does not work when No voltage Test the voltage switched on Impurities in the pump Remove the impurities housing Magnetic clutch is Specific gravity and/or Reduce the delivery rate;...
Les données techniques correspondent au descriptif du fabricant des moteurs. Les données techniques de moteurs similaires chez d´autres fabricants varient très peu. Ces données sont d´ordre général. Nr. / No. ProMinent Dosiertechnik GmbH · 69123 Heidelberg · Germany Datum / Date 05.12.2003 Page 22...
® ® Operating instructions ProMinent von Taine 0807 PP/PVDF 11.4 EC Declaration of Conformity Page...
Page 24
Addresses and delivery by the manufacturer / Adresses et liste des fournisseurs fourniesa par le constructeur / Para informase de las direcciones de los distribuitores, dirigirse al fabricante ® ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 • 69123 Heidelberg Germany Tel.: +49 6221 842-0 Fax.
Need help?
Do you have a question about the von Taine 0807 PP/FKM and is the answer not in the manual?