How To Read The At30 Model Number - HindlePower AT30 SERIES Operating And Service Instructions

Microprocessor-controlled three phase input float battery charger
Table of Contents

Advertisement

HOW TO READ THE AT30 MODEL NUMBER

The AT30 configured model number is coded to describe the unit's features and options. Please identify
the model number printed on the data nameplate decal, and write it in the spaces provided below.
AT30
A
B
Follow the chart below to determine the configuration of the AT30.
DESCRIPTION
CODE
A
SERIES
AT30
012
NOMINAL
024
B
DC OUTPUT
048
VOLTAGE
130
CODE
025
030
040
NOMINAL
C
DC OUTPUT
050
CURRENT
075
100
125
150
F
DC OUTPUT
E
D
FILTERING
S
U
208
240
480
AC INPUT
E
600
VOLTAGE
220
380
416
DESCRIPTION
CODE
INPUT AND OUTPUT INTERRUPTING CAPACITY RATINGS
CIRCUIT
ORDER
BREAKER
CODE
TYPE
S
STANDARD
M
MEDIUM AIC
H
HIGH AIC
* Contact your sales representative 500-600 Vac 60Hz circuit breaker AIC ratings.
NOTICE
.
The factory-configured model number printed on the AT30 data nameplate decal does not
feature certain options and accessories. Nor does it feature any field-installed options. Check off below
any options and/or accessories that are initially included, or are installed after shipment.
wall/rack-mounting brackets
NEMA Type 2 drip shield
NEMA Type 4 (12/13) cabinet
cabinet heater strips
pad/key lock for front panel door
analog ac voltmeter w/sel switch
analog ac ammeter w/sel switch
Please find the serial number on the
data nameplate and record it here:
C
D
E
FEATURE
AT30 BATTERY CHARGER
12 Vdc
24 Vdc
48 Vdc
130 Vdc
FEATURE
CODE
FEATURE
25 Adc
200
200 Adc
30 Adc
250
250 Adc
40 Adc
300
300 Adc
50 Adc
400
400 Adc
75 Adc
500
500 Adc
100 Adc
600
600 Adc
125 Adc
800
800 Adc
150 Adc
1K0
1,000 Adc
(STANDARD w/BATT)
FILTERED
(w/o BATTERY)
ELIMIN ATOR
SPECIAL 30 mV R MS (at 130V BATT)
UNFILTERED
208 Vac 60 Hz
240 Vac 60 Hz
480 Vac 60 Hz
550-600 Vac 60 Hz
220 Vac 50/60 Hz
380 Vac 50/60 Hz
416 Vac 50/60 Hz
FEATURE
AC CIRCUIT
DC CIRCUIT
BREAKER RATINGS
BREAKER RATINGS
(208/240/480 Vac) *
(125/250 Vdc)
5,000 AIC
5,000 AIC
25,000 AIC
10,000 AIC
65,000 AIC
20,000 AIC
zero-center ground detection meter w/test switch
end of discharge alarm relay
battery discharge alarm relay
barrier type auxiliary alarm terminal block(s)
external temperature compensation probe
DNP3 Level 2 / Modbus communications module
forced load sharing interconnection cable
F
G
H
J
K
DESCRIPTION
CODE
S
AC CIRCUIT
M
BREAKER
F
RATING
H
(SEE TABLE)
0
F
AC FUSES
G
(200 kAIC)
X
S
DC CIRCUIT
M
BREAKER
H
RATING
H
(SEE TABLE)
0
DC FUSES
F
J
(20 kAIC)
X
A
AUX ALARM
K
RELAY BOARD
X
G
COPPER
L
GROUND BUS
X
L
LIGHTNING
M
ARRESTOR
X
F
FUNGUS
N
PROOFING
X
S
STATIC
P
PROOFING
X
DESCRIPTION
CODE
OPTIONAL AC
FUSE RATING
(208-600 Vac)
200,000 AIC
L
M
N
P
FEATURE
STANDARD
MEDIUM AIC
HIGH AIC
NO AC BREAKER
SUPPLIED
NOT SUPPLIED
STANDARD
MEDIUM AIC
HIGH AIC
NO DC BREAKER
SUPPLIED
NOT SUPPLIED
SUPPLIED
NOT SUPPLIED
SUPPLIED
NOT SUPPLIED
SUPPLIED
NOT SUPPLIED
APPLIED
NOT APPLIED
APPLIED
NOT APPLIED
FEATURE
OPTIONAL DC
FUSE RATING
(12/24/48/130 Vdc)
20,000 AIC

Hide quick links: