Cover unused connections with the cover caps supplied.
Only connect plugs and other components that fulfill protection class IP
67 and that are certified for a temperate range from -20 °C to +55 °C.
2.2.1

Setting up the device

Set up/mount the device in a location where the ambient conditions spec-
ified in the technical data are adhered to.
2.2.2

Wall mounting

Prepare the drill holes at the installation point.
Mount the device on a level surface with four M5 screws.
Figure 3: BAT54-F wall mounting
2.2.3

Mounting the device outdoors

Note: Set up the antenna close to the device. Use the shortest antenna cable
possible.
Note: Problems with cable-free installations outdoors are usually due to re-
duced performance caused by corrosion processes in the antenna cable and
the cable connectors.
Therefore, you should always seal the outdoor cable connectors with water-
resistent tape.
Pole mounting
The BAT54-F devices are designed for pole mounting with the additional
BAT54-F pole mounting set
The BAT 54 pole mounting set is designed for:
Pole diameter: 37 mm to 60 mm
Maximum permitted wind load: 220 km/h.
BAT54-F
Release
12/07
(see on page 37
"Accessories").
21