Supervisory and Alarm Currents
Model
Module
4008-9101
Standard fire alarm control panel
4008-9102
4008-9121
Control panel with 24 LED Annunciator
4008-9122
4008-9801
Expansion Power Supply
4008-9802
Expansion Relay Module
City Circuit Module with disconnect
4006-9805
switch
City Circuit Module without disconnect
4006-9806
switch
Remote LCD Annunciator (see data
4606-9101
sheet S4606-0001)
Remote LED/Switch Annunciator (see
4610-9111
data sheet S4610-0001)
** Current Calculation Information:
1.
To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads.
2.
To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads
and all auxiliary loads.
Addressable Device Information
The following addressable device types and hardware point types are provided. A combination of autoprogram, and either
front panel or PC programming allows the operation to be selected per application.
Available Fire Detection Device Types
Device
Description
Photoelectric
TrueAlarm operation with
Addressable
sensitivity = 2.5%/ft
Detector
Fixed temperature thermal
Heat Detector
detection at 135° F (57.2° C)
Photoelectric
Detector with
Combination detector, dual address base with options available per above
Heat Detector
Addressable Hardware Point Types
Function Type
Description
FIRE
Fire monitor device
WATER
Waterflow monitor device
HEAT
Heat detector device
DUCT
Duct detector device
PULL
Manual (pull) station device
SMOKE
Smoke detector device
SO
Sprinkler Supervisory
Individual Addressable
IAM
Module
SIGNAL
Signal IAM
RIAM
Addressable Relay
Supervisory
135 mA + 0.8 mA per IDNet device
153 mA + 0.8 mA per IDNet device
50 mA
10 mA per energized relay
30 mA
30 mA
65 mA
40 mA
Options
Sounder base (selectable
for single station operation)
With relay output
Sounder base (selectable
for single station operation)
With relay output
Function Type
Description
WSO
Combination waterflow and water supervisory device
SUPV
Supervisory monitor
UTIL
Supervised utility monitor
TROUBLE
Trouble monitor
Verified fire alarm; an alarm level causes the alarm
VSMOKE
verification cycle to start
STYLEC
Style C fire monitor
Latching supervisory monitor (supervisory latches
LATSUPV
until system is reset)
ISOL
Addressable Isolator
MBZAM
Class B addressable IDC monitor module
MAZAM
Class A addressable IDC monitor module
ADRPUL
Addressable manual station
6
Alarm
190 mA + 1 mA per IDNet device
240 mA + 1 mA per IDNet device
60 mA
10 mA per energized relay
60 mA
60 mA
140 mA
70 mA
(all LEDs and tone-alert on)
With communications isolator
Selectable for all detectors to be at city of
Boston sensitivity of 3.7%/ft
With communications isolator
Individually selectable to add rate-of-rise heat
detection of 15° F/minute (8.3° C/minute)