5.2

Removing the bus connector

Requirements
● Diagonal cutter
● Slotted screwdriver with blade width < 2.5 mm
Procedure
Illustration similar
1. Carefully cut through the cable ties with a diagonal cutter and remove the cable tie. Take
care that you do not damage the cable.
2. Insert the slotted screwdriver into the opening on the bus connector (depending on which
bus connector is used).
3. Hold back the locking bolt of the bus connector with the slotted screwdriver. Press the
slotted screwdriver slightly to the left to do this.
4. Pull the bus connector of the cable out of the socket of the 3RW5 communication module.
Result
You have disconnected the 3RW5 communication module from the bus connection.