14
IMPORTANT: Setting a switch
When setting a switch to either the On or Off position,
apply firm pressure to make sure it is fully in position.
Switch bank SW1
1
Not used
2
NC set-up
3
Drip rejection
4
Spindle r/min
Switches
On
Off
Not used.
On
Off
Used when setting up an NC4 or NC4+ system. Set
this switch to On so that the alignment voltage can be
maximised. After maximising the voltage, set the switch
to Off so that the automatic gain circuitry can fine-tune
the operating voltage.
On
Off
When the drip rejection mode is set to On, the effects
of individual drops of coolant on measurements are
filtered out.
NOTE: For safe operation, set the spindle speed and
spindle override as described below.
500
1000
Used with drip rejection. For safe operation, the spindle
speed must be fixed at a whole multiple, e.g. 1000,
2000, or 3000; or 500, 1000, or 1500, and the spindle
override must be disabled.