Advertisement

IMPORTANT: Setting a switch

When setting a switch to either the On or Off position, apply firm pressure to make sure it is fully in position.

Switch bank SW1

Switch
On
1
Not used
On
2
NC set-up
On
3
Drip rejection On
4
Spindle r/min 500

Switch bank SW2

CAUTIONS:
With the SSR output switch(es) set to Off, i .e . normally open (N .O .), the respective output will remain in a
non-triggered state if the power supply is interrupted and/or a poor connection is made to the SSR .
If using SSR2 as an oscillating or pulsed output for a trigger signal to the control, the level output SSR1
must be used to guarantee a reliable probe status check .
Switch
On
1
SSR1
N .C .
2
SSR2
N .C .
3
SSR2
Level
Type1
4
Pulse width
20 ms 100 ms Sets the pulse width to either 20 ms or 100 ms (For more
2-8
NCi-6 non-contact tool setting interface: NCi-6 basics
Off
Off
Not used .
Off
Used when setting up an NC unit . Set this switch to On so that the
alignment voltage can be maximised . After maximising the voltage,
set the switch to Off so that the automatic gain circuitry can set the
operating voltage .
Off
When the drip rejection mode is set to On, the effects of individual
drops of coolant on measurements are filtered out.
NOTE: For safe operation, set the spindle speed and spindle
override as described below .
1000
Used with drip rejection . For safe operation, the spindle speed must
be fixed at a whole multiple, e.g. 1000, 2000, or 3000; or 500, 1000,
or 1500, and the spindle override must be disabled .
Off
N .O .
Sets the SSR output to either normally closed (N .C .) or normally
open (N .O .) .
N .O .
As above .
Pulsed Sets the SSR2 output to level or pulsed .
Refer to page 2-9 .
information see chapter 3, "System installation") .
M-code 3 may be used to invert the switch setting .
NOTE: For the cycle to work, the pulse width value selected must
be the same as the value that is configured in the tool setting
software .