Amana ATX 518 VW Service Manual page 27

V model international top mount refrigerators
Table of Contents

Advertisement

Component Testing
Component
Description
Heater, evaporator
Activated when defrost thermostat,
(defrost)
defrost timer, and freezer control
complete circuit through heater.
Heater, center
Wired in series with moisture control
mullion
switch (energy saver switch).
Help prevent condensation on center
mullion.
Ice Maker
Optional on some models.
See " Ice Maker" section for service
information.
Motor, condenser Condenser fan moves cooling air across
condenser coil and compressor body.
Condenser fan motor is in parallel circuit
with compressor.
Motor,
Evaporator fan moves air across
evaporator fan
evaporator coil and throughout
refrigerator cabinet.
Evaporator fan is in a series circuit with
temperature control, defrost terminator,
and defrost heater.
Overload
Overload is a temperature and current
sensing device.
Overload opens when high current or
high compressor temperature is sensed.
After overload opens, reset can require
up to two hours depending on ambient
temperature and residual heat load in
compressor.
Relay (See PTC Relay)
Relay, PTC
When voltage is connected and relay is
cool, current passes through relay to
start winding.
After a short time, current heats the
resistor in relay and resistance will rise
blocking current flow through relay.
Start winding remains in the circuit
through run capacitor.
Solid state relay plugs directly on
compressor start and run terminals.
Relay terminals 2 and 3 are connected
within relay. Run capacitor is connected
to relay terminal 3. L2 side of 230 VAC
power is connected to relay terminal 2.
Switch,
Single pole, single throw switch
refrigerator light,
completes circuit for light when door is
freezer light
open.
Test Procedures
Check resistance across heater.
To check defrost system
1.
Thermocouple defrost thermostat and plug refrigerator into wattmeter.
2.
Force into defrost mode. Wattmeter should read specified watts (according
to tech sheet).
When defrost thermostat reaches specified temperature ±9°C (±5°F) (see
3.
tech sheet), thermostat should interrupt power to heater.
Check resistance across heater.
Check resistance across coil.
1.
Disconnect power to unit.
2.
Disconnect fan motor leads.
3.
Check resistance from ground connection solder. Trace to motor frame
must not exceed .05 ohms.
4.
Check for voltage at connector to motor with terminator and temperature
control closed.
1.
Disconnect power to the refrigerator.
2.
Remove relay cover and pull relay off compressor. Pull overload protector
off compressor common terminal.
3.
With ohmmeter, check resistance between male terminal and female pin
receptacle terminal which pushes onto compressor common terminal. At
ambient room temperature overload protector should have less than 1 ohm
resistance. An open overload protector will have infinite resistance.
1.
Disconnect power to the refrigerator.
2.
Remove relay cover and disconnect leads.
3.
Check resistance across terminals 2 and 3 with an ohmmeter:
Normal = 3 to 12 ohms
Shorted = 0 ohms
Open = infinite ohms
Check resistant across terminals.
Switch arm depressed
" NO" terminals
Switch arm up
" NO" terminals
27
Open
Closed
RS5280001 Rev. 0