Technical data
Contact (standard)
Namur sensor (Specified for EX zones)
14.9

Motor data

Electrical data
58
Contact loading, max.
at voltage
Maximum current
30 V DC
1 A
The contact is an opener.
The contact is an potential-free.
For safety reasons we recommend connecting to a pro‐
tective low voltage, e.g. in accordance with EN 60335-1
(SELV ).
The cable can be poled as required.
5–25 V DC, in accordance with Namur or DIN 19234, potential-free
design.
Data
Rated voltage *
Power consumption - active surface
uncovered
Power consumption - active surface cov‐
ered
Rated switching distance
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
The monitor / power supply must be able to evaluate the cur‐
rent variations to indicate a diaphragm rupture!
For motor data - refer to the nameplate.
Motor data sheets, special motors, special motor flanges,
external fan, temperature monitoring
For further information for the motor with identity code
specification "S", refer to the motor data sheet in the
Appendix. Motor data sheets can be requested for all
other motors.
For motors other than those with identity code specifica‐
tions "S", "M" or "N": Pay special attention to the oper‐
ating instructions for the motors.
Special motors or special motor flanges are possible on
request.
Value Unit
8 VDC
> 3 mA
< 1 mA
1.5 mm