Technical data
Contact (standard)
Namur sensor (Specified for EX zones)
14.9
Motor data
Electrical data
58
Contact loading, max.
at voltage
Maximum current
30 V DC
1 A
The contact is an opener.
The contact is an potential-free.
For safety reasons we recommend connecting to a pro‐
–
tective low voltage, e.g. in accordance with EN 60335-1
(SELV ).
The cable can be poled as required.
–
5–25 V DC, in accordance with Namur or DIN 19234, potential-free
design.
Data
Rated voltage *
Power consumption - active surface
uncovered
Power consumption - active surface cov‐
ered
Rated switching distance
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
The monitor / power supply must be able to evaluate the cur‐
rent variations to indicate a diaphragm rupture!
For motor data - refer to the nameplate.
Motor data sheets, special motors, special motor flanges,
external fan, temperature monitoring
For further information for the motor with identity code
–
specification "S", refer to the motor data sheet in the
Appendix. Motor data sheets can be requested for all
other motors.
–
For motors other than those with identity code specifica‐
tions "S", "M" or "N": Pay special attention to the oper‐
ating instructions for the motors.
Special motors or special motor flanges are possible on
–
request.
Value Unit
8 VDC
> 3 mA
< 1 mA
1.5 mm