13
Checking and adjustment aid
.06
Fig. 13 - 02
Turn the handwheel until the needle bar is approximately in the required position.
Fit the adjustment gauge 1 as shown in Fig. 13-02; move the handwheel gently back and
forwards if necessary until the adjustment gauge fi ts properly.
The adjustment gauge 1 (order no. 95-752 474-05) can be used to fi x the nee-
dle bar in the needle rise position (needle bar is positioned 1.8 mm after b.d.c.).
1
Adjustment