Indicator Led - Denso GT10Q-SB User Manual

2d code handy scanner
Table of Contents

Advertisement

(2) Adjusting the beeper volume
You can adjust the beeper volume to three levels--high, medium and low, using the QR-coded parameter menu or
configuration software (ScannerSetting_2D).
Note: Enabling the Bluetooth interface with the "Start operation" QR Code symbol allows the beeper volume
adjustment.
Each time the "Beeper volume" QR Code symbol is read, the beeper volume cycles as shown below. The factory
default is High.
Turning the scanner power off does not affect this setting.
8.2

Indicator LED

The indicator LED lights or flashes in blue, green, red or orange as described below.
The indicator LED lights in blue when:
- the scanner has read a code successfully,
- the "Start setting" or "End setting" QR Code symbol is read from the QR-coded parameter menu (given in Chapters
13 and 14),
- the scanner starts or ends a sequence of split QR Code scanning, or
- the scanner has read a split QR Code symbol.
The indicator LED lights in green when:
- data transfer is started by the data retransfer function,
- the scanner has read a code successfully with the readable code switching function or barcode reader mode switching
function enabled,
- data transfer is started by the specific character transfer function, or
- you hold down the magic key for at least approx. 2 seconds to make the scanner ready to accept entry of a master
code in the data verification mode.
The indicator LED lights in red when:
- a command error has occurred,
- code data read does not match the master data in the data verification mode,
- a master code has the wrong number of digits during entry of master data,
- the data retransfer function failed to transfer data,
- a code other than a parameter setting code is read during parameter setting by the QR-coded parameter menu,
- you press the magic key that has been disabled by a control command (refer to Appendix 2) specifying any trigger
switch operating mode other than continuous reading modes 1 and 2 even though the ready/standby switching
function has been assigned to the magic key, or
- the scanner is locked due to a mismatch in the data verification mode.