6 Mounting/Installation
6.5

Operation with the S-ND control unit

Optionally the micro annular gear pump mzr-2942 can be delivered with the
controller S-ND.
The controller S-ND controls the number of revolutions to achieve a constant
flow rate or positions the motor for precise dosage volumes. Values can be set
with the help of a potentiometer or with the external control signal 0-10 V.
Second a serial interface allows the control of precise feeding and dosing tasks
by an external PC. Included in the delivery volume are diskettes with a
Windows
dosing tasks by defining dosing data. A zero modem cable is included in the
delivery volume to connect the pump controller S-ND with a PC.
Controller S-ND
Power supply
Max. continuous current
Max. peak current
Velocity range
Input No. 1
Analog velocity command
Digital velocity command
Output/Input No. 2
Input No. 3
Memory for programs
*) Values are limited in the controller software
Table 24
Technical data controller S-ND
The control unit permits an easy startup of the pump with:
 the possibility to connect the voltage supply to the delivered DIN socket
 the possibility to connect the voltage supply with screw clamps
 a 10-pole connector assembly for the motor cable
 speed set with potentiometer
 analog voltage signal 0-10 V for speed control at the screw clamps
 9-pole connection plug for the RS-232 interface
 error output with status LED, programmable also as trigger input with screw
 tumbler switch S1 for the connection of digital input No. 3 of the motor
 screw clamps for the connection of digital inputs No. 3, 4, 5 of the motor
32
®
based software. The software enables the operator to manage
connections
control unit
control unit
Technical data subject to change without prior notice!
U
B
I
dauer
I
max
Input resistor
Voltage signal
PWM Signal
Frequency range
Error state
no error
Programmed as an input
Logic level
Operating manual mzr-2542 / mzr
12 – 24
336*)
600*)
1 ... 6000*)
18
 10
low 0 ... 0.5 / high 4 ... 30
100 ... 2000
max. U
/ 30 mA
B
switched to GND
low 0 ... 0.5 / high 4 ... U
B
low 0 ... 0.5 / high 4 ... 30
7936
Last update: January 2016
-
2942
V
mA
mA
rpm
k
V
V
Hz
V
V
Bytes