Without prior explicit written permission of HNP Mikrosysteme GmbH no part of this manual may be, copied, reproduced or processed. This manual has been prepared with care. HNP Mikrosysteme does assume no liability for any errors in this manual and resulting consequences. Likewise, no liability is assumed direct or subsequent damages arising from an incorrect use of the devices.
Contents Operating manual mzr-2965, mzr-4665 Contents General Information Application scope of the pumps Product information Measurements Flow chart Technical data of the micro annular gear pumps Technical data of the drive 1.6.1 Pin assignment with connector 1.6.2 Pin configuration in housing version...
Page 4
Contents Operating manual mzr-2965, mzr-4665 6.5.3 Startup with an external 0(4)-20 mA current signal 6.5.4 Startup with external potentiometer 6.5.5 Startup with the RS-232 interface 6.5.6 Startup of the pump units with network mode (NET1 Command) Start Up / Shut Down...
Page 5
Contents Operating manual mzr-2965, mzr-4665 Declaration of media in contact with the micro annular gear pump and its components Appendix Last update: August 2019 Technical data subject to change without prior notice!
In case assistance is needed, please indicate the pump type visible on the housing. Application scope of the pumps The micro annular gear pumps mzr-2965 and mzr-4665 described in this manual are suitable for continuous delivery of water, watery solutions, solvents, methanol and varnishes as well as many other liquids.
1 General Information Operation manual mzr-2965, mzr-4665 Product information This manual is valid for the micro annular gear pumps mzr-2965 and mzr-4665 manufactured by HNP Mikrosysteme GmbH, Bleicherufer 25, D-19053 Schwerin, Germany. The bottom line of this manual shows issue and date of issue of the manual.
*) Values are specified for oil with viscosity 16 mPas. Differing specifications on request **) Customized solutions on request. table 1 Technical data of the micro annular gear pumps mzr-2965 and mzr-4665 The material properties of a liquid (e.g. viscosity, lubricating property, particle Warning content, corrosiveness) impacts the technical data and the lifetime of pumps.
1 General Information Operation manual mzr-2965, mzr-4665 Technical data of the drive The micro annular gear pumps 2965 and -4665 are provided with a mzr- canned motor with integrated motion controller. The motor uses a high dynamic of the micro annular gear pump. With the internal control unit it is possible to manage lower RPM ranges down to 10 RPM.
1 General Information Operation manual mzr-2965, mzr-4665 1.6.1 Pin assignment with connector Pin Motor Function Pin Stecker 3.In Digital input 3 24 VDC Power supply +24 VDC (5 – 30 VDC) AnIn Analog input AGND Analog GND Fault Fault output...
1 General Information Operation manual mzr-2965, mzr-4665 1.6.2 Pin configuration in housing version figure 6 View housing version Pinout Description Plug / socket Digital input +24 V Analog input Analog GND Fault output RS-232 RxD RS-232 TxD table 3 Pin assignment on delivery with 8-pin M12 plug...
2 Safety instructions Operation manual mzr-2965, mzr-4665 Safety instructions Please comply not only with the general safety instructions listed below, but also with specific safety instructions mentioned in the following chapters. Safety symbols in this operating manual Non respect of the safety instructions marked with the following signs...
6.5. Should a malfunction of the mzr-pump occur, do not dismantle the pump on Warning your own but contact one of HNP Mikrosysteme service staff for professional assistance. Unauthorized pump conversions and spare part manufacture Conversions or modification to the device are only permitted with prior consent of the manufacturer.
2 Safety instructions Operation manual mzr-2965, mzr-4665 Improper modes of operation The safety of operation of the delivered device can only be insured by correct use, as described in chapter 1. The limit values given in this manual must not be exceeded in any case.
Transport In order to avoid any transport-related damage, the package must be protected against shocks. HNP Mikrosysteme guarantees that all goods leave the factory in the best condition. Any noticed damage should be reported to the concerned forwarding agent, authorized dealer or to HNP Mikrosysteme as manufacturer.
4 Description of the pump Operation manual mzr-2965, mzr-4665 Description of the pump Principle of the Micro annular gear pumps Micro annular gear pumps are positive displacement pumps. They contain two rotors bearing slightly eccentrically to each other; an externally toothed internal rotor and an annular, internally toothed external rotor (see figure 7).
Page 19
4 Description of the pump Operation manual mzr-2965, mzr-4665 efficiency is dependent on the media and the pressure against which it has to be fed. Example: The pump mzr-4665 feeds with its displacement volume of 12 µl with 3000 RPM and a volumetric efficiency of 100 % referring to the above- mentioned formula the flow rate of 36 ml/min.
4 Description of the pump Operation manual mzr-2965, mzr-4665 liquid inlet liquid outlet (suction side) (pressure side) figure 9 Indication of the turning direction and fluidic connections on the front of the micro annular gear pump Micro annular gear pump...
4 Description of the pump Operation manual mzr-2965, mzr-4665 Materials and liquids The components of the micro annular gear pump heads are manufactured of tungsten carbide (with 10% nickel binder) and nickel bronze. The liquid resistance is to be checked in single cases. Feeding of non-lubricant liquid reduces the service life of the micro annular gear pumps.
Page 22
4 Description of the pump Operation manual mzr-2965, mzr-4665 figure 11 Drawing manifold assembly M2.1 The dimensions for installation space are shown in the drawing installation space in the appendix 20. Warning When installing the pump, ensure that there is no gap between manifold adapter and fixing support located.
5 Optional modules Operation manual mzr-2965, mzr-4665 Optional modules The spectrum of applications of the magnetic hermetic micro annular gear pump series may be expanded by using different additional modules. The modules allow for special dosage tasks, which could otherwise not be accomplished with a standard pump version.
5 Optional modules Operation manual mzr-2965, mzr-4665 By-pass module (optional) The by-pass module allows constant minimal volume dosage with flow rates in the nanoliter range. The technology is based on the division of flow generated by the micro annular gear pump, according to the relationship of fluidic resistance of two predefined capillaries.
Page 25
5 Optional modules Operation manual mzr-2965, mzr-4665 mzr-2521 / mzr-2921 Master capillary ID: 0.25…0.5 mm By-pass socket stainless steel 316L with a manifold assembly, Length: 80…300 mm fixture openings 4 x M3 ( 22 mm) Return line to the liquid tank Side capillary ID: 0.064…0.25 mm...
− Operating temperature range If you notice any difference between the required and the delivered pump type, please contact HNP Mikrosysteme. Do not put the pump into operation without prior approval. Mounting of the micro annular gear pump The mounting of the micro annular gear pump can be vertical or horizontal. For...
When you want to operate the pump in reverse direction please contact HNP Mikrosysteme since this is not possible in any application. 3. The suction line should be installed ascending to the pump for better degassing.
HNP Mikrosysteme offers a choice of standard filters covering a broad spectrum of applications. You may count on our assistance for the selection of the most suitable filter.
In order to operate the pump a supplementary source of 24 VDC will be required. The ampacity of the voltage source should amount to around 3 A for the micro annular pumps mzr-2965 and mzr-4665. The micro annular gear pump is connected via the Terminal Box S-G05. This enables an easy startup of the pump due to: −...
Page 30
6 System integration Operation manual mzr-2965, mzr-4665 alternative serial power supply interface 24 V DC of PC RS-232 Power In RS-232 Power In 24 VDC 24 VDC Term inal Box S-G05 Term inal Box S-G05 HNP M ikrosystem e Gm bH...
6 System integration Operation manual mzr-2965, mzr-4665 Installation of the cable wires tool: screwdriver blade 2.5 x 0.4 mm open the spring clamp with the screwdriver through the side slot cable in cable opening place (cable can be used with or without...
6 System integration Operation manual mzr-2965, mzr-4665 Remarks: − You may adjust speed of the micro annular gear pump without the need to connect it to the serial interface. − In case error occurs for example due to motor overload - the green status LED on the Terminal Box S-G05 will turn red.
6 System integration Operation manual mzr-2965, mzr-4665 6. Connect the 24 VDC voltage supply to the terminal or to the DIN connector. Make sure that the polarity of the supplied direct current is correct, otherwise electronics will be damaged. The input circuit at the analog input is layed out as a differential amplifier. If the analog input is “open”...
Page 34
6 System integration Operation manual mzr-2965, mzr-4665 serial alternative interface power supply of PC 24 V DC RS-232 RS-232 Power In Power In 24 VDC 24 VDC Term inal Box S-G05 Term inal Box S-G05 HNP M ikrosystem e Gm bH...
6 System integration Operation manual mzr-2965, mzr-4665 6.5.4 Startup with external potentiometer 1. Connect the drive with the eight colored wires to the terminal box S-G05. The colors of the corresponding wire connections are described in the table 8. 2. Bring the internal potentiometer knob to the null position by turning it clockwise to the limit stop.
6 System integration Operation manual mzr-2965, mzr-4665 The input circuit at the analog input is layed out as a differential amplifier. If the analog input is “open” there is already a voltage of 2 V. That means in this case that the motor would be turning at a speed of about 2000 rpm. In order to set 0 rpm the input must be connected over a low ohm resistor to the analog ground (AGND) or connected to the AGND-voltage level.
6 System integration Operation manual mzr-2965, mzr-4665 6.5.6 Startup of the pump units with network mode (NET1 Command) All standard units are delivered with node number 0. In order to prepare the units for network operation, they must first be individually connected to the PC and set to the desired node address using the FAULHABER Motion Manager.
Page 38
6 System integration Operation manual mzr-2965, mzr-4665 While connecting the DC voltage pay attention to the correct polarity, otherwise electronics may be damaged. − Remarks: − Controller which the manufacturer specifically shipped for the network modus were with the command NET1, SOR0, ANSW0 and DIPROG programmed.
Depending on the application for example water, or isopropanol may be used. If you have doubts whether a liquid is suitable for this function or not, please ask the manufacturer of the liquid or HNP Mikrosysteme. Last update: August 2019...
Page 40
7 Start Up / Shut Down Operation manual mzr-2965, mzr-4665 Flushing cycle Selection of flushing liquid (FL) Right see table 10 (Selection of the flushing liquid) flushing liquid Is the see table 11 (Resistance of the sealing materials) pump resistant?
Page 41
7 Start Up / Shut Down Operation manual mzr-2965, mzr-4665 Nature of the handled liquid Flushing cycle Suitable flushing liquid [min] Oils, fats, plastifiers 15-20 isopropanol, ethanol, acetone, benzine Solvents (polar + nonpolar) 5-10 isopropanol, ethanol Other organic liquids 10-15...
7 Start Up / Shut Down Operation manual mzr-2965, mzr-4665 Shutdown of the micro annular gear pump During the shutdown of the pump the following steps should be followed − Flush the pump with a filtered and particle-free flushing liquid (solvent) (see chapter 7.3)
Page 43
7 Start Up / Shut Down Operation manual mzr-2965, mzr-4665 End of test/operation Flushing cycle Drain the pump Selection of flushing liquid (FL) Pump Right requires see table 11 flushing flushing? liquid Flushing cycle Is the see table 12 pump...
7 Start Up / Shut Down Operation manual mzr-2965, mzr-4665 7.4.1 Conservation If the micro annular gear pump operates at irregular intervals or for other reasons should be put out of operation for a longer period, it should, after service and flushing procedure (see chapter 7.3), be filled in with a suitable conservation liquid.
7 Start Up / Shut Down Operation manual mzr-2965, mzr-4665 Liquids isopropanol solvent for organic compounds, cosmetics, essential oils, waxes and esters, antifreezers, antiseptic agents acetone solvent for a number of organic compounds, unlimited solubility in water, dissolves natural and synthetic resins, fats,...
− by changing the operating direction of the pump. If these measures turn out to be ineffective, please contact the service staff of HNP Mikrosysteme (see chapter 13) and send the pump back to the manufacturer for inspection. You should under no condition try to dismantle the pump by yourself. This...
® After a successful installation the program »mzr-pump controller« can be found in the start menu under »Programs - HNP Mikrosysteme«. After the program has been initiated, data such as the pump type »mzr-2505«, »mzr-2905«, »mzr-4605«, »mzr-7205« and the gear reduction should be set.
Page 48
8 Software »mzr-pump controller« Operation manual mzr-2965, mzr-4665 annular gear pump may be initiated with the »Start« button or by pressing the enter key for the indicated »Duration« value. Checking of the »endless« box will put the pump to continuous operation. The »Stop« button or pressing of the enter key once again will stop the delivery.
9 Software »Motion Manager« Operation manual mzr-2965, mzr-4665 Software »Motion Manager« The »Motion Manager« software enables operation and configuration of the drive and offers a possibility of an online graphic analysis of the operating data. The software is delivered on CD. The program may be installed on a PC running under Windows 7 ®...
Page 50
In case of the mzr-2965 and mzr-4665 micro annular gear pumps 1 revolution of the rotor corresponds to 3000 steps. For more details concerning the operation of the Motion Manager, please read the online program help.
9 Software »Motion Manager« Operation manual mzr-2965, mzr-4665 Programming of the control The control of the micro annular gear pump may be adapted by the user to a specific task by means of an easy programming language. The program files are available in the ASCII code and have by default the »mcl«...
Page 52
9 Software »Motion Manager« Operation manual mzr-2965, mzr-4665 figure 28 Transfer of the mcl files as parameter data When a window appears with the enquiry if the mcl files should be transferred to the »Motion-Controller«, answer by clicking on the »Yes« button.
Page 53
9 Software »Motion Manager« Operation manual mzr-2965, mzr-4665 A CD with sample mcl programms is possible to deliver with the Motion Manager. At the delivery the pump has a standard program configuration. Moreover, a sample program that may be started with an external switch is available for discrete dosage tasks.
Non-liability clause HNP Mikrosysteme GmbH shall not be liable for damages resulting form the non-respect of instructions comprised in this operating manual. It remains at the responsibility of the user to conform to all laws, rules and regulations in force.
12 Problems and their removal Operation manual mzr-2965, mzr-4665 Problems and their removal Disturbance Cause Solution 1 The pump does not start operation. No power supply Check the power supply. 2 The pump does not deliver any No liquid in the primary tank.
Page 56
12 Problems and their removal Operation manual mzr-2965, mzr-4665 Disturbance Cause Solution Air bubbles in the liquid delivery system Fill in the pump and the liquid delivery system (tubing, valves) with liquid. 6 Dosage volume does not Air bubbles in the liquid delivery system Vent the liquid delivery system and check for correspond to the desired values.
Page 57
If a disturbance that has not been mentioned in the above list, or that makes the use of the micro annular gear pump unsafe appears, please stop the operation of the pump without delay and contact HNP Mikrosysteme (see chapter 13). If needed return the pump to the manufacturer for checkup.
13 EU Directive Operation manual mzr-2965, mzr-4665 EU Directive A Directive or EU Directive is a legal instrument of the European Community addressing at the member states and forcing them to implement specific regulations or targets. Leastwise, micro annular gear pumps are covered, by the...
Operation manual mzr-2965, mzr-4665 REACH regulation (EU) No. 1907/2006 HNP Mikrosysteme is not a manufacturer or importer of chemical substances subjected to registration, but in terms of regulation, a downstream user. As downstream user, we conduct the necessary communication with our suppliers to ensure future deliveries of all components necessary to us.
13 EU Directive Operation manual mzr-2965, mzr-4665 13.1.2 Information on use as intended For micro annular gear pumps, note the following: Requirement for the intended operation is the operation according to the technical data and the manual. Restrictions If the micro annular gear pumps are used at home, in business or in commerce...
14 Declarations of conformity Operation manual mzr-2965, mzr-4665 Declarations of conformity The delivered micro annular gear pump falls within scope of the following EU directives: − Machinery Directive (2006/42/EU) − EMC Directive (2014/30/EU) You may request the declarations of conformity for the micro annular gear pumps from us separately.
Page 63
This statement does not warrant any characteristics in terms of product liability. Please note the safety instructions in the manual. Mr. Lutz Nowotka, HNP Mikrosysteme GmbH, Bleicherufer 25, D-19053 Schwerin is authorised to compile the technical file according to Annex VII A.
Page 65
We hereby declare that the following micro annular gear pumps of the magnetic hermetic series: mzr-2965, mzr-4665 are intended for installation into another machinery/plant and that start of operation is forbidden till it is identified that the machinery/plant into which these micro annular gear pumps shall be installed corresponds to the regulations of the EU guidelines regarding safety and health requirements.
For service and maintenance please return your micro annular gear pump to HNP Mikrosysteme. You will find the address on the cover of the present operating manual. The declaration of media (liquids) having had contact with the micro annular gear pump and components must imperatively be completed.
16 Contact person Operating manual mzr-2965, mzr-4665 Contact person Development and application assistance, service and accessories Mr. Sven Reimann Phone +49| (0) 385|52190-349 Service and maintenance Mr. Steffen Edler Phone +49| (0) 385|52190-307 Drive and control technology Mr. Lutz Nowotka...
17 Legal information Operating manual mzr-2965, mzr-4665 Legal information Marks ® is a registered German trademark of HNP Mikrosysteme GmbH. MoDoS is a registered German trademark of HNP Mikrosysteme GmbH. ® µ-Clamp ® is a registered German trademark of HNP Mikrosysteme GmbH.
18 Safety information for the return of already employed micro annular gear pumps and components Operating manual mzr-2965, mzr-4665 Safety information for the return of already employed micro annular gear pumps and components 18.1 General information The operator carries the responsibility for health and safety of his/her employees.
Page 71
19 Declaration of media in contact with the micro annular gear pump and its components Operating manual mzr-2965, mzr-4665 Declaration of media in contact with the micro annular gear pump and its components Type of the device Pump type/article no.:...
Page 72
20 Appendix Operating manual mzr-2965, mzr-4665 Appendix − Layouts Technical data subject to change without prior notice! Last update: August 2019...
Page 73
20 Appendix Operating manual mzr-2965, mzr-4665 figure 30 Data sheet of the micro annular gear pumps mzr-2965 / mzr-4665 with slip fittings Last update: August 2019 Technical data subject to change without prior notice!
Page 74
20 Appendix Operating manual mzr-2965, mzr-4665 figure 31 Data sheet of the micro annular gear pump mzr-2965 / mzr-4665 with the manifold assembly M2.1 Technical data subject to change without prior notice! Last update: August 2019...
Page 75
20 Appendix Operating manual mzr-2965, mzr-4665 figure 32 Data sheet of the micro annular gear pump version IP65 Last update: August 2019 Technical data subject to change without prior notice!
Page 76
20 Appendix Operating manual mzr-2965, mzr-4665 figure 33 Installation space mzr-2965/4665 Technical data subject to change without prior notice! Last update: August 2019...