EN50131 Compliant installations
1. The TL280R, TL280 module is monitored by the control panel
and it is programmed via the programming menu (* 8, section
[851] in the control panel. The interface is connected to the PC-
Link bus as shown in the diagram included in this manual.
2. The Ethernet port is protected against surge transients up to
2.5kV and it is immune to conducted and radiated RF fields with
levels up to 10V/m as tested per EN50130-4 Standard.
3. The TL280R, TL280 module conforms with radiated emissions
levels for Class B equipment as per standards EN61000-6-3/
EN55022/CISPR22.
© 2015 Tyco Security Products. All Rights Reserved.
Toronto, Canada
www.dsc.com
Tech Support: 905-760-3000
4. The TL280R, TL280 module uses AES128 encryption and
heartbeat supervision for both the Ethernet communication path
and it meets security levels S2 as per EN50136-2-1 (EN50131-1).
It also uses authentication for each message exchanged with the
compatible receiver equipment at ARC and it meets level I2 for
information security.
5. The TL280R, TL280 module has only one communication
path: Ethernet 10/100BaseT using Internet/Intranet network.
TL280 and TL280R have been certified by Telefication in accor-
dance with EN50131-1 requirements for Grade 2, Class II and
ATS Class 3,4,5.