Setting The Lcd Display; Monitoring Products - Growatt 2000-US Operation Manual

Hide thumbs Also See for 2000-US:
Table of Contents

Advertisement

6.2 Setting the LCD display

The inverter can support three kinds of knock: single knock, double knock. Each kind
of knock has different function. Refer to specified definition in Table below
Knock type
Single knock
Double knock
Before light the background, the types of knock functions are the same: just
light the background.
That the background light will automatically off if there is no knock detected in 10
seconds.
Sound control can define the display language, luminance of the display, and
utility model choice. When the LCD is dark, Knock and double knock make it
becomes bright. Knock to make it display next information or change the set
situation. Double knock make the display stand for 30 second, enter to setting the
menu.
Setting language
Knock to make the display bright
"language: English" knock to select the language you need and wait until the
display become dark.
Setting luminance of the display
Knock to make the display bright
enter "LCD contrast 2" knock to select the luminance you need and wait until the
display become dark.
Setting communication address
Knock to make the display bright-->knock to "COM Address: xx" -->double knock to
change the Address model-->clock to set address.
Setting grid model choice
This function is disable when the inverter work in the normal state, you much turn off
the AC separate unit, and the inverter LCD will display a error "NO AC Connection" ,
LED turn red ,then this model choice function is enable.
Knock to make the display bright
enter "Net Model: xx" knock to select the grid model .need to wait for 10S till the
CPU restart.
Then check the "NET Model" in LCD display again.
Turn on the AC separate unit, inverter begin to work.
33
Definition
Key Down
Key SET
knock to "set language" double knock to enter
knock to "set LCD contrast" double knock to
knock to "Net Model: xx"
double knock to
Power :
Net
Model: 2
Power :
Net
Model: 3
Power :
2016.2w
Net
Model: 4

7.1 Monitoring Products

7.1.1 Shine Net
Shine NET is a PC software that communicate with inverter to analyze the inverter
working state. It is convenient for you to know the inverter's real-time working state
and the history work information.
Specification:
Communicate with inverter by RS232 and Bluetooth.
Construct net with inverter, GRO monitor and Shine NET by RS232, Bluetooth and
Internet.
Two Interfaces: Multi Inverter Interface and Wave Data Interface.
In Multi Inverter Interface: See at most 4 inverters working data at the same time, you
can select your own compare inverters and parameters.
In Wave Data Interface: Query the inverter real time and history power wave,work
data and error information.
Multi languages: English, French, German, Spanish and etc.
Support OS: WinXP/ Vista/win7/2000/2003.
Communications
Communications
2016.2w
2016.2w
7
7
34