Trouble shooting
Trouble shooting
Sometimes, the PV inverter does not work normally, we recommend the following
solutions for common troubleshooting. The following table can help the technician
to understand the problem and take action.

Error message

Description
No AC Connection
No utility grid
connected or utility
grid power failure.
AC V Outrange
Utility grid voltage
is out of
permissible range.
AC F Outrange
Utility grid
frequency out of
permissible range.
Over Temperature
Temperature
outrange
Insulation problem
PV Isolation Low
Output High DCI
Output current DC
offset too high
Residual I High
Leakage current
too high
PV Voltage High
The DC input
voltage is exceeding
the maximum
tolerable value.
43
Suggestion
1.Check AC wiring,
especially the ground wire
2.ContactGrowatt.
1.Check grid typ and voltage.
2.If the error message still
exists despite the grid voltage
being within the tolerable
range, contact Growatt.
1.Check grid frequency.
2.If the error message is
displayed despite the grid
frequency being within the
tolerable range, contact
Growatt.
1.check the inverter operation state
2.If the error message is displayed
still,please contact Growatt.
1.Check if panel enclosure ground
properly.
2.Check if inverter ground properly.
3.Check if the DC breaker gets wet.
4.If the error message is displayed
despite the above checking passed,
contact Growatt.
1.Restart inverter.
2.If error message still exists, contact
Growatt.
1.Restart inverter.
2.If error message still exists, contact
Growatt.
Disconnect the DC switch
immediately.
Error: 100
2.5V reference
voltage fault
Error: 101
Communication fault
Slave processor can't
receive data from
Master processor.
Error: 102
Consistent fault. Data
received by Master and
Slave processor are
different. The reason can
be utility grid voltage or
frequency change
frequently.
Error: 116
EEPROM fault
Error: 117
Relay fault
Error: 118
Init model fault
Error: 119
GFCI Device Damage
Error: 120
HCT fault
Error: 121
Communication fault.
Master processor can't
receive data from Slave
processor.
Error: 122
Bus voltage fault
1.Restart inverter
2.If error message still
exists, contact Growatt.
1.Restart inverter
2.If error message still
exists, contact Growatt.
1.Restart inverter.
2.If error message appears
frequently or error
message still exists after
replacement, check utility
grid. if you require help,
contact Growatt.
3.If error message still
exists, contact Growatt.
Contact Growatt.
Contact Growatt.
Contact Growatt.
Contact Growatt.
Contact Growatt.
1.Restart the inverter
2.If error message still
exists, contact Growatt.