Lcd Display Icons - Growatt SPF 5000T DVM-MPV User Manual

Off grid solar inverter split phase 4kw-12kw
Table of Contents

Advertisement

LCD Display Icons

Icon
Input Source Information
Configuration Program and Fault Information
Output Information
Battery Information
In AC mode, it will present battery charging status.
Status
Constant
Current mode /
Constant
Voltage mode
Floating mode. Batteries are fully charged.
16
Indicates the AC input.
Indicates the PV input
Indicate input voltage, input frequency, PV voltage, battery voltage and
charger current.
Indicates the setting programs.
Indicates the warning and fault codes.
Warning: flashing with warning code.
Fault:lighting with fault code
Indicate output voltage, output frequency, load percent, load in VA, load in
Watt and discharging current.
Indicates battery level by 0-24%, 25-49%, 50-74% and 75-100% in battery
mode and charging status in line mode.
These two signs indicate the charge priority. SOLAR indicates solar first.
UTILITY indicate utility first. SOLAR blinking indicates solar only; SOLAR and
UTILITY both on indicates combined charging.
Battery voltage
<2V/cell
2 ~ 2.083V/cell
2.083 ~ 2.167V/cell
> 2.167 V/cell
Function Description
LCD Display
4 bars will flash in turns.
Bottom bar will be on and the other three
bars will flash in turns.
Bottom two bars will be on and the other
two bars will flash in turns.
Bottom three bars will be on and the top
bar will flash.
4 bars will be on.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents