Fixed The Inverter On The Wall; Check Inverter Installation Status; Electrical Connection - Growatt 2000-US Operation Manual

Hide thumbs Also See for 2000-US:
Table of Contents

Advertisement

Fix the mounting frame as the figure shows. Do not make the screws to
be flush to the wall. Instead, leave 2 to 4mm exposed.

5.4 Fixed the inverter on the wall

Falling equipment can cause serious or even fatal injury,
never mount the inverter on the bracket unless you are
sure that the mounting frame is really firmly mounted on
WARNING
the wall after carefully checking.
Rise up the inverter a little higher than the bracket. Considered the
weight of them. During the process please maintain the balance of the
inverter.Hang the inverter on the bracket through the match hooks on
bracket.
17
After confirming the inverter is fixed reliably, fasten four M6 safety-lock
sokets head cap screws on the left and right side firmly to prevent the
inverter from being lifted off the bracket.

5.5 Check Inverter Installation Status

Check the upper straps of inverter and ensure it fits on to the bracket.
Check the secure mounting of the inverter by trying to raise it from the
bottom. The inverter should remain firmly attached.
Choose a strong mounting wall to prevent vibrations while inverter is
operating.

5.6 Electrical Connection

5.6.1 Safety
Danger to life due to lethal voltages!
High voltages which may cause electric shocks are
present in the conductive parts of the inverter. Prior
DANGER
to performing any work on the inverter, disconnect
the inverter on the AC and DC sides
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

3000-us1500-us

Table of Contents