Installing The Computing Unit - Siemens SIMATIC PC 670 Equipment Manual

Computing unit
Hide thumbs Also See for SIMATIC PC 670:
Table of Contents

Advertisement

Release 04/02
2.2

Installing the Computing Unit

The unit delivered
panels.
The computing units with AC power supply meet the requirements of the fire
protection housing complying with EN60950. It can therefore be installed without
an additional fire enclosure;
The computing units with a DC power supply are considered open operating
resources (right side of device); therefore, the assembly design must fulfill the fire
protection housing requirements.
Please observe the following points when installing your device:
S Avoid extreme ambient conditions as far as possible. Protect the device from
dust, moisture and heat.
S Do not expose your device to direct sunlight.
S The device must be installed in such a way that it presents no danger of any
kind (for example, by tipping over).
S The clearance around the device must be at least 100 mm to make sure it is
sufficiently ventilated.
S Never cover the ventilation slots.
S Observe the installation locations allowed when you install your device.
Warning
!
If systems are installed at a non-approved installation location, the approvals to
UL 1950 and EN60950 are no longer valid!
Panel PC 670 Computing Unit, Equipment Manual
is particularly suited for installation in consoles, cabinets and
Starting Up the Computing Unit
2-3