Hardware Information
Assignment of display to display select pins
Automatic configuration of one of 15 possible displays is performed by means of
the Display Select inputs. The Display Select inputs have pull-up resistors – in
other words, if these inputs are not connected, they go to High. The input has to be
connected to GND for them to go Low.
Pin No.
LCD_SEL3 LCD_SEL2 LCD_SEL1 LCD_SEL0 Display type
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
7-22
Low
Low
Low
Low
Low
Low
Low
Low
Low
High
Low
High
Low
High
Low
High
High
Low
High
Low
High
Low
High
Low
High
High
High
High
High
High
High
High
Low
Low
reserved
Low
High
reserved
High
Low
reserved
High
High
reserved
Low
Low
640 x 480 (VGA), TFT, 18
bit
Low
High
reserved
High
Low
1024 x 768 (XGA), TFT,
18 bit
High
High
800 x 600 (SVGA), TFT,
18 bit
Low
Low
reserved
Low
High
reserved
High
Low
reserved
High
High
reserved
Low
Low
reserved
Low
High
reserved
High
Low
reserved
High
High
No display /
DDC selected display