I/O interface for front control elements
All the signals necessary for the connection of front control elements, in addition to
the display and USB ports, are applied to this port. The maximum cable length is
50 cm at a USB data rate of 12 Mbaud.
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Panel PC 670 Computing Unit, Equipment Manual
Short Name
Meaning
GND
Chassis ground
P12V
Power supply for inverter
BL_ON
Backlight on (5V = On)
P5V_fused
+5V ( fused)
GND
Chassis ground
P3V3_fused
+3.3V (fused)
K_CLK
Keyboard clock
K_DATA
Keyboard data
M_CLK
Mouse clock
M_DATA
Mouse DATA
P5V_fused
+5V ( fused)
USB_D1M
USB data- channel 1
USB_D1P
USB Data+ port 1
GND
Chassis ground
LCD_SEL0
Display type select signal 0
LCD_SEL1
Display type select signal 1
LCD_SEL2
Display type select signal 2
LCD_SEL3
Display type select signal 3
RESET_N
Reset signal (Low active)
SPEAKER
Connection for system speaker
HD_LED
HD LED, anode with 1k in series
on motherboard
DP_LED
MPI/DP LED, anode above 1k in
series on motherboard
Ethernet_LED
Ethernet LED, anode above 1k in
series on motherboard
TEMP_ERR
LED temperature error, anode with
1k in series on motherboard
RUN_R
LED watchDog error, anode with
1k in series on motherboard
RUN_G
LED watchdog o.k., anode with
1k in series on motherboard
Hardware Information
Input/Output
-
Output
Output
Output
-
Output
Output
Input/Output
Output
Input/Output
Output
Input/Output
Input/Output
-
Input
Input
Input
Input
Input
Output
Output
Output
Output
Output
Output
Output