9.1.1.4
Changing bearings when using permanently lubricated rolling-contact bearings
Note
Permanently lubricated bearings
The replacement of the permanently lubricated roller bearing is determined by the number of
operating hours and is required around every three years.
9.1.2
Maintenance
9.1.2.1
Safety instructions for maintenance
Personal protective measures when working with compressed air
When cleaning with compressed air, dust, metal chips, or cleaning agents can be whirled
up. Injuries can result.
When cleaning using compressed air, make sure you use suitable extraction equipment
and wear protective equipment (safety goggles, protective suit, etc.).
Note
Operating conditions and characteristics can vary widely. For this reason, only general
intervals for inspection and maintenance measures can be specified here.
See also
The five safety rules: (Page 11)
9.1.2.2
Maintenance intervals
General
Careful and regular maintenance, inspections, and overhauls are essential for detecting and
eliminating faults in good time before they can cause any damage.
A5E02605207A AA
Siemens AG Operating Instructions V1.0 1PH8
CAUTION
Maintenance
9.1 Inspection and maintenance
57