3.4

Ethernet interfaces X5/ X7

The multi-axis control system CMXR-C2 has two Ethernet interfaces with RJ45.
-
X5 without gateway for local networks
-
X7 with gateway for higher-level networks
3.4.1

IP address on delivery

The CMXR multi-axis control system has, on delivery, a minimal installation on the memory
card so that the network connection can be established after connection to the power
supply. The network settings are pre-assigned as follows:
-
X5 deactivated
-
X7 activated
To establish a connection to the CMXR multi-axis control system, the corresponding
network settings have to be undertaken on the PC.
3.5

USB interfaces X8/ X10

The CMXR-C2 has 2 USB interfaces:
 The USB port X8 for saving and restoring programmes as well as for removing
diagnostic information if servicing is required. Further information can be found in
the CDSA software manual.
 The USB port X10. It is reserved and cannot be used.
Festo GDCP-CMXR-C2-SY-EN 1205b
Note
The use of an Ethernet switch is recommended for minimising the
load for the Ethernet network.
Note
The CMXR-C2 multi-axis control system is not DHCP-capable.
Caution
X5 and X7 may not be located in the same network
Network parameter X7
IP address
Subnet mask
Gateway address
Table 3.4: Preset network parameters X7
Value
192.168.100.100
255.255.255.0
0.0.0.0