3. Modular multi-axis control system CMXR-C2
3.4
Ethernet interfaces X5/ X7
The multi-axis control system CMXR-C2 has two Ethernet interfaces with RJ45.
-
X5 without gateway for local networks
-
X7 with gateway for higher-level networks
3.4.1
IP address on delivery
The CMXR multi-axis control system has, on delivery, a minimal installation on the memory
card so that the network connection can be established after connection to the power
supply. The network settings are pre-assigned as follows:
-
X5 deactivated
-
X7 activated
To establish a connection to the CMXR multi-axis control system, the corresponding
network settings have to be undertaken on the PC.
3.5
USB interfaces X8/ X10
The CMXR-C2 has 2 USB interfaces:
The USB port X8 for saving and restoring programmes as well as for removing
diagnostic information if servicing is required. Further information can be found in
the CDSA software manual.
The USB port X10. It is reserved and cannot be used.
Festo GDCP-CMXR-C2-SY-EN 1205b
Note
The use of an Ethernet switch is recommended for minimising the
load for the Ethernet network.
Note
The CMXR-C2 multi-axis control system is not DHCP-capable.
Caution
X5 and X7 may not be located in the same network
Network parameter X7
IP address
Subnet mask
Gateway address
Table 3.4: Preset network parameters X7
Value
192.168.100.100
255.255.255.0
0.0.0.0
19