2) Irregular Operation Of The Device After Turning On The Power; Irregular Operation Of The Device After Turning On The Power; No Operation - Olivetti d-Color P116 Service Manual

Table of Contents

Advertisement

7.4.2.(2)

Irregular Operation of the device after turning on the power

(2-1)

No operation

Confirmation Items
(2-1-1) Peripheral check of power supply
AC power supply supplied to
the printer.
Voltage setting of low-voltage
power supply unit (100V/
230V ).
The 5V power supply and
24V power supply supplied to
the main board (TB3 PCB).
Y110260-4
Confirmation Tasks
Confirm the supplied voltage of the AC power supply.
Measurement of the supplied AC voltage.
Confirm the power supply setting of the equipment used.
(Confirm the short plug of low-voltage supply setting switch.
Short plug Have/None=100V /230)
Confirm the power supply by the POW1 connector of the main
board (TB3 PCB).
3, 4pin: 24V
5, 6pin: 5V
7, 8, 9pin: 0VL
1, 2 pin: 0VP
d-Color P116 Service Manual
Action at NG
Supply the AC power
supply.
Adjust the low-voltage
power supply setting.
Exchange low-voltage
power supply.