Normal Self-Diagnostic Mode (Level 1) - Olivetti d-Color P116 Service Manual

Table of Contents

Advertisement

5.3.2 Normal self-diagnostic mode (Level 1)

The menus of the normal self-diagnostic mode are indicated below.
Item
1
Switch scan
test
2
Motor clutch
test
3
Execution of
test print
4
Color drift
correction test
5
Density
correction test
6
Indication of
consumable
part counter
7
Indication of
consumable
part
continuance
counter
8
Factory/
Shipping mode
switching
9
Check of Fuse
status
10
Engine
parameter setup
98
Table 5-3 Maintenance Utility Adjustment Items
Self-diagnosis Menu
SWITCH SCAN
Checking of inlet sensor and switch
MOTOR&CLTCH
Operation test of motor and clutch
TEST
TEST PRINT
Print of test patterns built in PU
REG ADJUST TEST
Judgment of good/bad color drift
correction mechanism.
DENS ADJ TEST
Judgment of good/bad density
correction mechanism.
CONSUMABLE
Indication of consumed state of
STATUS
consumables
PRINTER STATUS
Indication of lifetime consumed state
of consumables
FACTORY MODE
Switching between Factory mode
and Shipping mode
SET
Indication of the status of each fuse
SENSOR SETTING
Setup of Enable/Disable of error
detection by various sensors
d-Color P116 Service Manual
Adjustment
Maintenance Utility
ML3600n
(With a Panel)
No.19
No.20
Not operable
No.21
No.21
No.14
No.14
No.3
No.25
No.26
Y110260-4

Advertisement

Table of Contents
loading

Table of Contents