Download Print this page

Siemens Pointek CLS200 Quick Start Manual page 9

Digital. capacitance switches
Hide thumbs Also See for Pointek CLS200:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Quick Reference: operating functions using input keypad
Function,
Mode
(parameter in PDM)
1
M
2
Measured value display
Error display
2
*
Sensor test
Open Edit mode, or
4
Rise Time
increment digit.
Open Edit mode, or
5
Fall Time
increment digit.
10
*
HW Write Protection
13
*
Display Source
14
*
Unit
Node address (PROFIBUS
Open Edit mode, or
15
only)
increment digit.
16
*
PROFIBUS Ident Number
1
M
0% Application Range
19
setting
100% Application Range
20
setting
Alarm output trigger
23
*
Contact type
24
*
Switch Point 1
(Rising Edge)
25
OFF to ON
Switch Point 2
26
(Falling Edge)
ON to OFF
27
*
Local Status Text
1.
Press  to store numerical values; press M to store a selection (indicated by asterisk *).
2.
L appears in Mode indicator field if HW Write Protection is enabled.
3.
If L or LA appear after disabling HW Write Protection, local operation is locked via the bus. Use PDM to disable this lock.
Page EN-8
Pointek CLS200/300 (Digital) – QUICK START MANUAL
Key function
Either key activates test
Move cursor to right, or decrement digit, or
store edited value.
Move cursor to right, or decrement digit, or
store edited value.
Either key enables Write Protection
Increment or decrement value to make selection
Increment or decrement value to make selection.
Move cursor to the right, or decrement digit, or
store edited value.
Increment or decrement value to make selection.
Open Edit mode, or
Move cursor to the right, or decrement digit, or
increment digit.
store edited value.
Open Edit mode, or
Move cursor to the right, or decrement digit, or
increment digit.
store edited value.
Increment or decrement value to make selection.
Increment or decrement value to make selection.
Open Edit mode, or
Move cursor to the right, or decrement digit, or
increment digit.
store edited value.
Open Edit mode, or
Move cursor to the right, or decrement digit, or
increment digit.
store edited value.
Increment or decrement value to make selection.

 and 
Default startup display; or if Sensor selected in Mode 13
Error, if transmitter is disturbed
Displays GOOD or FAIL D
and value (seconds)
Range: 0.0 to 100.0 s
and value (seconds)
Range: 0.0 to 100.0 s
Hold for 5
– –
2
seconds to
L
3
disable
0 = OUT parameter;
2 = sensor;
Select
Assign slave address on the PROFIBUS-line (0 to 126)
Select device mode: according to profile; or, according to profile with full device
specific support.

 and 
Adjust lower limit of application range.
Adjust upper limit of application range.
Select diagnostic interrupt (dIAG); process interrupt (OUt_d); disabled (OFF): or
diagnostic alarm limit (set in PDM) exceeded (ALErt)
Set contact functionality in case of event: (logical inversion of alarm output switch)
- Make contact (CLOSE) / Break contact (OPEn)
Set % of range at which switch will change from OFF to ON. (Hysteresis is a
difference in value between Switch Point 1 and 2).
Set % of range at which switch will change from ON to OFF.
(Hysteresis is a difference in value between Switch Point 1 and 2).
Select presentation of the status text.
Pointek CLS200/300 (Digital) – QUICK START MANUAL
Display/ explanation
= disabled (parameter changes permitted)
= enabled (parameter changes inhibited)
1 = primary value;
3 = electronics temperature
o
o
o
C;
F;
R, or K (if 3 selected in Mode 13).
7ML19985XA02

Advertisement

loading

This manual is also suitable for:

Pointek cls300