Hardware Installation Guide for the Polycom SoundStructure
Fax: (012) 711 0872
Taiwan
For connection in Taiwan, Polycom requires the use of external surge protection on the PSTN
telecommunication interfaces connected to the TEL1 and TEL2 cards.
Polycom recommends the APC (American Power Conversion) ProtectNet PTel2 for this purpose. Details
may be found at www.apc.com.
For use with the TEL2 interface card, the PTEL2 device will provide protection for both lines if a cable with
the following pinout is used on both sides of the surge protector:
RJ45 pin 3 and 4 to RJ11 (6 pin) pin 3 and 4
RJ45 pin 5 and 6 to RJ11 (6 pin) pin 3 and 4.
For use with the TEL1 interface card, the PTEL2 device will provide protection for the PSTN line if a cable
with the following pinout is used on both sides of the surge protector:
RJ45 pin 3 and 4 to RJ11 (6 pin) pin 3 and 4.
Properly Connect the Surge Suppressor
The surge suppressor is directional and must be connected in accordance with the
supplied instructions. The connection of the earth lead on the surge suppressor to
an effective earth bonding point is a requirement of its correct operation.
Warning
Rest Of World
EMC. CLASS A ITE
WARNING
This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Installation Instructions
Installation must be performed in accordance with all relevant national wiring rules
Plug acts as Disconnect Device
The socket outlet to which this apparatus is connected must be installed near the equipment and must
always be readily accessible
Warranty Information
LIMITED WARRANTY
Polycom warrants to the end user ("Customer") that the product will be free from defects in workmanship
and materials, under normal use and service, for one year, or such longer period as Polycom may announce
Polycom, Inc.