REDWALL®
MegaRed® 180 Dual Range detector Model LRP 180QH
Installation and Set-up Instructions
(Please keep for future reference)
DESCRIPTION
Model LRP 180QH is designed to detect human movement at ranges of up to 180 metres. The rugged housing
contains two separate detectors. One detector is similar to the popular REDWALL LRP 100Q quad sensor which
has a detection range up to 100 metres. The other detector is also a 'quad' sensor system with a long focal
length optical system specifically designed to detect movement at ranges between 80 and 180 metres.
The LRP 180QH is ideal for use with CCTV surveillance systems which have multi-cameras or domes with pan,
tilt and zoom facilities. The two outputs (near and far) may be used to automatically activate camera pan or
zoom controls to precisely locate an intruder over the full detection range. Alternatively, the two outputs may be
used to direct an operator to a specific area of interest or to activate local floodlighting.
The LRP 180QH comprises two units, the detector head and the control unit which contains three relays for 'near',
'far' and tamper signalling. The control unit may be located remote from the detector head, for instance at a
control/monitoring area, or may be located close to the detector or camera where direct automatic pan or zoom
is used.
Connection between head and control unit is 4-core screen cable which may be up to 1400 metres. (See cable
chart Fig. 6). Alarm signalling between the detector head and the control unit is by means of simple line current
monitoring which is highly immune to radio and electrical interference.
Fig. 1 shows the coverage patterns of the two detectors. At the recommended mounting height of 8 feet (2.5
metres) there will be an area directly below the unit extending some 6 metres where an Passive Infrared
2M
3M
4M
AT 30M
AT 100M
AT 180M
'NEAR' DETECTOR
'FAR' DETECTOR
PLAN VIEW
0.5°
'FAR' DETECTOR
8FEET
'NEAR' DETECTOR
2.5M
Fig. 1

Advertisement

Table of Contents
loading

Summary of Contents for Optex Redwall LRP 180QH

  • Page 1 REDWALL® MegaRed® 180 Dual Range detector Model LRP 180QH Installation and Set-up Instructions (Please keep for future reference) DESCRIPTION Model LRP 180QH is designed to detect human movement at ranges of up to 180 metres. The rugged housing contains two separate detectors. One detector is similar to the popular REDWALL LRP 100Q quad sensor which has a detection range up to 100 metres.
  • Page 2: Installation

    detectors ultimate detection range will vary according to the background temperature and the size, speed and clothing of the intruder. The LRP 180QH is designed and tested to detect a normally clothed, normal size adult, moving at slow or medium walking pace across the zones. Variations in size and clothing, background temperature, speed and direction of motion may result in the ultimate detection range being less (or more) than 180 metres.
  • Page 3 RANGE ADJUSTMENT Fig. 3 Fig. 4 POWER ON FAR LED NEAR LED TAMPER LED Fig. 5 IMPORTANT MR 240 IF ALL CABLES ARE AT MAX. PERMITTED RESISTANCE ENSURE THAT INPUT VOLTAGE AT TERMINALS IS NOT LESS THAN 11 VOLTS CONTROL MAX.
  • Page 4: Initial Testing

    CONNECTIONS Fig. 5 shows the terminal layout of the control unit. The three relays provide voltage-free change-over (form C) (S.P.D.T.) contacts rated 1 Amp. at 30V MAX. WARNING!!! DO NOT CONNECT MAINS POWER TO ANY TERMINALS. If the control unit is located a long way from the head and heavy (1.5 or 2.5mm) cables are used, it is recommended that the cables are terminated in a separate junction box and smaller gauge cables are taken into the control unit terminals.
  • Page 5 RANGE SETTING USING THE AUDIO WALK-TESTER OPM-WT The OPM-WT converts the voltage fluctuations at the detector into a changing audio tone. The tone pitch rises and falls as a zone is crossed. When the unit trips into alarm, the tone pitch suddenly rises. If there is no further movement the unit will re-set after some 10 seconds and the tone drop back to a lower pitch.
  • Page 6: Final Alignment

    FINAL ALIGNMENT The recommended procedure is as follows: Check that the mounting bracket is firm then slacken the pan bolts and pan the head to the desired direction. Firmly tighten both bolts. Slacken the two tilt bolts and adjust the range adjustment screw to ensure that the top surface of the head is parallel to the ground.
  • Page 7: Control Unit

    DIMENSIONS MEGARED HEAD 11.0” 8.8” 280 mm 223 mm 6.8” 173 mm 5.5” 3.15” 140 mm 80 mm 2.38” 60 mm CONTROL UNIT 4.9” 2.3” 125 mm 58 mm 4.45” 113.5 mm 2.0” 3.15” 52 mm 80mm ACCESSORIES OPM-WT Audio Walk-tester for Mege Red and REDWAVE. LRP Mega Hood Sun/Snow Hood.
  • Page 8: Product Specification Sheet

    These units are designed to detect movement of an intruder and activate an alarm control panel. Being only part of a complete alarm system,we cannot accept responsibility for any damages or other consequences resulting from an intrusion.These products conform to the EMC Directive 89/336 EEC. OPTEX CO., LTD. OPTEX INCORPORATED OPTEX (EUROPE) LTD.

Table of Contents