Configuration
Network A
Computer
A1
= Additional internal routes
IP address
192.168.11.3
Network mask
255.255.255.0
Network B
Computer
B1
IP address
192.168.15.2
Network mask
255.255.255.0
Network C
Computer
C1
IP address
192.168.27.1
Network mask
255.255.255.0
!
Further settings of the routers, e.g. internal routers for communication from
Network B to Network C, are not taken into consideration in the above example.
82 von 105
A2
A3
192.168.11.4
192.168.11.5
255.255.255.0
255.255.255.0
B2
B3
192.168.15.3
192.168.15.4
255.255.255.0
255.255.255.0
C2
C3
192.168.27.2
192.168.27.3
255.255.255.0
255.255.255.0
A4
A5
192.168.11.6
192.168.11.7
255.255.255.0
255.255.255.0
B4
Additional
internal routes
192.168.15.5
SINAUT
255.255.255.0
MD740-
1Network:
192.168.15.0/24
Gateway:
C4
192.168.11.2
192.168.27.4
Network:
255.255.255.0
192.168.27.0/24
Gateway:
192.168.11.2