Siemens SINAUT MD740-1 User Manual page 21

Table of Contents

Advertisement

!
In case
the Administrator
website does not
appear...
SINAUT MD740-1
If the browser still tells you after several attempts that the page
cannot be displayed, try the following:
Check the hardware connection.
To do so on a Windows computer, enter the following
command via the DOS prompt (menu Start, Programs,
Tools, Command Prompt):
ping 192.168.1.1
If there is no message about the reception of the 4 sent
packets within the prescribed time, check the cable, the
connections and the network card.
Make sure that the browser does not use a proxy server.
In MS Internet Explorer (Version 6.0) you make this setting as
follows: menu Tools, Internet Options..., Connections tab:
under LAN Settings click on the Settings button, in the
Settings for local area network (LAN) dialogue box make sure
that the Use a proxy server for your LAN entry is not
activated.
If there are other LAN connections active on the computer,
deactivate them for the duration of configuration.
Under Windows menu Start, Settings, Control Panel,
Network Connections / Network and Dial-up
Connections right-click on the appropriate icon and select
Deactivate in the context menu.
Enter the address of the SINAUT MD740-1 plus slash:
https://192.168.1.1/
Configuration
21 von 105