SINAUT MD740-1
If the browser still tells you after several attempts that the page
cannot be displayed, try the following:
•
Check the hardware connection.
To do so on a Windows computer, enter the following
command via the DOS prompt (menu Start, Programs,
Tools, Command Prompt):
ping 192.168.1.1
If there is no message about the reception of the 4 sent
packets within the prescribed time, check the cable, the
connections and the network card.
•
Make sure that the browser does not use a proxy server.
In MS Internet Explorer (Version 6.0) you make this setting as
follows: menu Tools, Internet Options..., Connections tab:
under LAN Settings click on the Settings button, in the
Settings for local area network (LAN) dialogue box make sure
that the Use a proxy server for your LAN entry is not
activated.
•
If there are other LAN connections active on the computer,
deactivate them for the duration of configuration.
Under Windows menu Start, Settings, Control Panel,
Network Connections / Network and Dial-up
Connections right-click on the appropriate icon and select
Deactivate in the context menu.
•
Enter the address of the SINAUT MD740-1 plus slash:
https://192.168.1.1/