Siemens SINAUT MD740-1 User Manual page 28

Table of Contents

Advertisement

Configuration
28 von 105
Setting a new rule
If you want to set a new rule, click on New.
Set the required rule (see below), then click on OK or Apply.
You receive a system message as confirmation.
You can make the following possible entries:
Protocol: All means: TCP, UDP, ICMP and others.
IP address: 0.0.0.0/0 means all addresses. To denote a range, use
CIDR syntax - see CIDR (Classless InterDomain Routing), page
79.
Port:
(is evaluated only with TCP and UDP protocols)
any means any port.
startport:endport (e.g. 110:120) denotes the port area.
Individual ports can be entered either with the port number or with
the corresponding service name: (e.g. 110 for pop3 or pop3 for
110).
Action:
Accept means that the data packets may pass.
Refuse means that the data packets are turned away so that the
sender is informed of the refusal.
Reject means that data packets are not allowed to pass. They
are "swallowed" so that the sender is not informed of their
whereabouts.
Log:
For each individual firewall rule you can determine whether, when
the rule is applied,
- the event is to be logged - set Log to Yes
- or not - set Log to No (default setting)
Log entries for unknown connection attempts:
This logs all connection attempts which are not recorded by the
prevalent rules.