Introduction; Application Examples; Features Of The Tof/Spot; Type Description - Cedes TOF/Spot Installation And Operation Manual

Hide thumbs Also See for TOF/Spot:
Table of Contents

Advertisement

Available languages

Available languages

TOF/Spot

4. Introduction

The TOF/Spot is a compact yet powerful single-spot
measuring system with the widest range of application
possibilities. It uses Time-of-Flight technology (TOF) to
ensure ultra reliable detection and exact detection range
setting, regardless of the background. This enables a
detection range of up to 6 m (20 ft).
The sensor can measure the exact distance at which
a person or object enters the detection area or it can
simply switch the output at a predefined level. This
means the potential application areas are immense: from
safeguarding the closing door edges of revolving doors,
to optimizing warehouse door opening times, to providing
touchless button functionality. Its small dimensions mean
the TOF/Spot is ideal as a built-in solution.
4.1

Application examples

• Closing edge of revolving doors
• Bus doors
• Closing edge of glass doors
Figure 1:
Typical TOF/Spot application environment
4.2

Features of the TOF/Spot

• Exact distance setting, independent of background
• Excellent detection capability
• Universal relay output
• Insensitive to ambient light
• Easy mounting
• Compact and sleek design
• Operating range of up to 6 m
• TÜV approved (TOF/Spot-S, safety version)
• Category 2, PL C (TOF/Spot-S, safety version)
4
4.3

Type description

TOF/Spot - a - bb - c - d - e, ff, range
TOF/Spot version
a
: -
Standard
S
Safety
Spot size at 2 m range
bb
: 40
40 mm x 40 mm
TOF/Spot type
c
: N
Potentiometer
P
Preset (value in m)
C
Automatic calibration
A
Analog
T
Teach-in
USB
Demo version
Output
d
: U
Universal (relay, PNP , NPN)
A
Analog
Housing
e
: Y
Snap-in
Supply power
ff
: AC
12 ... 24 VAC
DC
10 ... 30 VDC
, max. detection range
xx
Value in m
Figure 2:
TOF/Spot type description
4.4

Category 2 operation (TOF/Spot-S)

The TOF/Spot-S is certified by TÜV according to
EN 13849-1, Cat. 2, PLC ; EN 16005; DIN 18650 and
SIL 1 according to EN 61508.
However, there are certain requirements connected to this
certification:
• The system integrator has to define the correct
electrical connection to the controller to fulfill Cat. 2
operation.
• The sensor must be tested regularly by the controller
through the test input.
• For a safety application, the following mounting
options are valid for a category 2 application:
Figure 3:
Horizontal safeguarding with the TOF/Spot-S
Horizontal
© CEDES | V 2.0