8. Failures and remedial measures

Failure
The
splitting
force
insufficient to split the log.
The in-feed conveyor belt does
not move.
The output conveyor does not
move.
The cutting motion does not
fully cut the log.
The
saw
chain
properly sink into the wood.
The machine starts but none of
the
functions
work.
machine makes an abnormal
noise.
The electric motor does not
start.
The motor tends to stop, and
the thermal relay is easily
tripped.
Cutting blade will not start
rotating
Hakki Pilke 38 Pro
Cause
is
1. Log sideways
2. Machine overheated
3. Adjustment of the speed valve
faulty
1. The belt is too loose or is not
properly aligned.
1. The belt is too loose.
The path of the saw bar is
incorrectly adjusted.
does
not
1. The saw chain is dull.
2. The saw bar is crooked.
The electric motor runs in the
The
wrong direction.
1. The machine makes a loud
noise but does not start.
2. The input cable is faulty.
3. The thermal relay has tripped.
The thermal relay is broken or
incorrectly adjusted.
1. The machine guard is
2. 12 V power cable is not
35 / 40
open.
connected.
Translation
Remedial measure
1. Remove and replace
2. Check the hydraulic oil
temperature in the
machine and the filter
condition (see Section
5.3).
3. Contact the retailer.
1. Tension or adjust the belt
according to the instructions
in Section 5.4.1.
1. Tighten the belt according to
the instructions in Section
5.4.2.
.
Lower the path of the saw
bar.
1. Sharpen or replace the saw
chain.
2. File the bar to make it
straight.
See Section 3.2.2.
1. The gear fuse has blown.
Replace it.
2. Replace the cable.
3. Acknowledge the thermal
relay by pressing the red
Stop button of the starter
behind the machine.
Contact the retailer.
1. Close the guard.
2. Connect the power
cable.